检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:景艳[1] 郑艳芬[2] 王铁英[1] 魏宏英[1] 宁玮[1] 杨霞[1] 辛强[1]
机构地区:[1]内蒙古包头市第四医院超声医学科,014030 [2]包头医学院医学技术学院
出 处:《疑难病杂志》2015年第5期504-507,共4页Chinese Journal of Difficult and Complicated Cases
基 金:内蒙古自治区卫生和计划生育委员会医疗卫生科研计划项目(No.201301085)
摘 要:目的探讨增强型血流成像技术(E-flow)检测胎儿肺静脉方面的优势,评价产前检测胎儿肺静脉在筛选和协助早期诊断胎儿先天性心脏病中的临床应用价值。方法选择190例正常胎儿(正常胎儿组)和产前诊断为心脏发育异常的胎儿6例(先天性心脏病组),比较应用E-flow和多普勒彩色超声血流成像(CDFI)2种技术对胎儿肺静脉的显示情况,并测量及评价相关肺静脉血流参数。结果 16~24周胎儿肺静脉的显示率E-flow技术明显高于CDFI(χ~2=14.769,P<0.05);而24^(+1)~40周对肺静脉的显示率无统计学意义(χ~2=1.920,P>0.05)。肺静脉的内径随孕周增长而增宽,S峰、D峰及A波随孕周增长而增快;PI、PVI随孕周增长而逐渐降低。胎儿肺静脉内径及S、D、A与胎龄呈明显的正相关(r=0.973、0.959、0.944、0.950,P<0.05);PI、PVI与胎龄呈负相关(r=-0.821、-0.855,P<0.05)。先天性心脏病组肺静脉PI及PVI较胎龄相匹配的正常胎儿组较高,A波较低,2组比较差异有统计学意义(P<0.05)。结论应用E-Flow技术产前检查胎儿肺静脉,可更早更清晰地显示胎儿肺静脉的走行情况,对临床尽早诊断胎儿先天性心脏病提供有价值的信息。Objective To investigate the advantage of enhanced imaging techniques ( E-flow) in detection of fetal pulmonary vein,and to evaluate the clinical application value of prenatal detection of fetal pulmonary veins in screening and help for the early diagnosis of fetal congenital heart disease.Methods 190 cases of normal fetal ( normal fetus group) and 6 cases of prenatal diagnosed as fetal cardiac abnormalities ( congenital heart disease group) were enrolled, E-flow and color Doppler flow imaging (CDFI) were compared in display the fetal pulmonary veins, measured and evaluated the pulmonary ve-nous flow parameters.Results 16-24 weeks’ fetal pulmonary veins display rate, E-flow technology was significantly better than that of CDFI (χ2 =14.769, P〈0.05) 24 +1 -40 weeks on pulmonary vein display rate was not statistically significant (χ2 =1.920, P〉0.05) .Pulmonary vein diameter were grew with gestational age growth, S peak, D peak and A wave were went faster with the gestational age increased;PI and PVI gradually decreased with increase of gestational weeks.There were obvious positive correlation of fetal pulmonary vein diameter, S, D, A and gestational age ( r =0.973, r =0.959, r =0.944, r =0.950, P〈0.05);PI, PVI were negatively correlated with gestational age ( r =-0.821, r =-0.855, P〈0.05).CHD group’s pulmonary venous PI and PVI were higher than the gestational age matched normal fetal group, A wave was low, there was significant difference between the 2 groups ( P〈0.05) .Conclusion E-flow technology in antenatal ex-am the fetal pulmonary vein with advantage of earlier and more clearly show the path of fetal pulmonary veins, and provide val-uable for clinical early diagnosis of fetal congenital heart disease information.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117