Fenton法对丁苯橡胶废水中COD和磷的去除研究  被引量:5

Study on the removal of COD and phosphorus from styrene-butadiene rubber wastewater by Fenton method

在线阅读下载全文

作  者:王艳秋[1] 李明哲[1] 朱秀慧[1,2] 敖雪[1] 单明军[1] 

机构地区:[1]辽宁科技大学化学工程学院.辽宁鞍山114051 [2]营口理工学院化学工程系,营口115000

出  处:《工业水处理》2015年第5期42-44,共3页Industrial Water Treatment

摘  要:为解决丁苯橡胶废水处理不达标问题,采用Fenton试剂法对丁苯橡胶废水生化出水进行后续处理试验研究,考察初始pH、H2O2投加量、n(H2O2)∶n(Fe2+)、反应时间对COD、磷和SS去除率的影响。结果表明:Fenton试剂法处理丁苯橡胶废水,在初始pH为7,H2O2投加量为0.4mL,n(H2O2)∶n(Fe2+)为2∶1,反应时间为70min时,COD的去除率可达到81%左右,磷和SS的去除率接近100%。出水达到《污水综合排放标准》(GB8978—1996)一级排放标准。In order to solve the problem that the quality of the treated styrene-butadiene rubber (SBR) wastewater couldn't reach the discharge standard,the experimental research on the follow-up treatment of the biochemically treated SBR effluent by Fenton reagent method has been conducted. The effects of influencing factors, such as initial pH, H2O2 dosage, n (H2O2):n (Fe^2+) and reaction time on the removing rates of COD,phosphorus and SS are inves- tigated. The results from Fenton treatment of SBR wastewater show that when the initial pH is 7, H2O2 dosage 0.4 mL, n (H2O2):n (Fe^2+) 2:1, and reaction time 70 min, the removing rate of COD is about 81% and the removing rates of phosphorus and SS are both nearly 100%. The effluent indexes could reach the first class criterion specified in Integrated Wastewater Discharge Standard (GB 8978--1996).

关 键 词:FENTON试剂 丁苯橡胶废水 除磷 

分 类 号:X703.1[环境科学与工程—环境工程]

 