检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广东珠海金湾发电有限公司,广东珠海519050 [2]广东电网公司电力科学研究院,广东广州510080
出 处:《热力发电》2015年第5期125-128,共4页Thermal Power Generation
摘 要:某600 MW机组QFSN-600-2型发电机由于定子绕组端部振动大,导致水电接头脱焊引起短路接地故障。通过振动测试分析,判断该振动源于50 Hz转子机械振动通过轴承、基座传递到定子绕组端部,传递过程由于结构共振导致振动超标。对此,采取改变定子绕组端部刚度、降低激振力及加装阻尼装置等措施,将定子绕组的端部振动最大值控制在150μm以内。Due to large vibration of stator end winding,the stator ground protection faults occurred twice in QFSN-600-2 600 MW generator in a 600 MW unit. Vibration tests show that,the mechanical vibration with frequency of 50 Hz transmitted from the bearing,base to the stator end winding,during this process the structural resonance caused excess vibration. Thus, a series of measures were taken to control the maximum value of turbine generator stator end winding vibration to a safe level,including changing the stator winding end stiffness, reducing the excited forces and installing damping devices. After these measures were taken,the maximum vibration was reduced to below 150 μm.
关 键 词:QFSN-600-2型发电机 定子 绕组端部 振动 激振力 阻尼
分 类 号:TK268.1[动力工程及工程热物理—动力机械及工程]