作 者:靳冰洁[1] 张步涵[1] 姚建国[2] 杨胜春[2] 邓韦斯 邵剑[1]
机构地区:[1]强电磁工程与新技术国家重点实验室,华中科技大学,湖北省武汉市430074 [2]中国电力科学研究院(南京),江苏省南京市210003
出 处:《电力系统自动化》2015年第5期61-68,共8页Automation of Electric Power Systems
基 金:国家电网公司科技项目(dz71-13-036)~~
摘 要:现代大规模电力系统面临着多种不确定性因素,它们给系统带来的扰动已成为系统安全运行的主要威胁之一。针对这一问题,提出一种大型电力系统元件脆弱性评估的新方法:在改进信息熵的基础上,结合含风电电力系统的灵敏度分析及支路容量裕度,研究节点扰动功率安全转移的分布信息,建立衡量节点抗扰动能力的节点脆弱性评估指标;在此基础上,通过补偿法将支路开断转化成两端节点的虚拟注入功率扰动,并采用熵权法将其与节点脆弱性评估结果相结合,提出支路脆弱性综合评估方法。通过IEEE 300节点系统算例,验证了方法的快速有效性,同时分析了影响系统关键元件脆弱性的因素,为电力系统中的误差控制和运行管理提供了参考。The modern large-scale power system is confronted by many kinds of uncertainty factors, the disturbance brought by which has become one of the major threats to safe operation of the system. In view of this problem, a new method of large- scale power system component vulnerability assessment is proposed. Based on the improved entropy and by referring to a sensitivity analysis of the wind power system and branch capacity margin, the distribution information on disturbance power safe transfer is investigated to establish the node vulnerability assessment indicator for measuring the ability of node to resist disturbance. On this basis, the branch outage is translated into virtual power injection disturbance on the two-terminal nodes by the compensation method. The branch vulnerability is then assessed with the entropy weight method by combining with node vulnerability assessment. Results of an IEEE 300-bus system case study have validated the effectiveness and quickness of the presented method. The factors that influence the key element vulnerability are analyzed, providing reference for error control and operation management in power systems.
关 键 词:大型电力系统 脆弱性 信息熵 灵敏度 补偿法 熵权
分 类 号:TM73[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7