检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张德成[1]
出 处:《中国实用医刊》2015年第13期39-40,共2页Chinese Journal of Practical Medicine
摘 要:目的探讨采用非限制型全膝关节假体治疗僵直型膝关节的临床疗效。方法选择2011年6月至2013年6月收治的17例僵直型膝关节患者的临床资料,全部患者均给予应用非限制型全膝关节假体手术治疗。结果本组患者手术时间(91±11)min,手术失血量(350±45)ml,术后仅1例患者出现切口边缘少许发黑现象。给予全部患者6周~1年随访,患者治疗前后膝关节屈曲与HSS评分比较差异有统计学意义(P〈0.05)。结论采用非限制性全膝关节假体治疗僵直型膝关节,疗效较为满意,是较为有效的治疗方法。Objective To evaluate the clinical efficacy of the use of non-limiting total knee prosthesis on stiff knee. Methods The clinical data of 17 patients with stiff knee from June 2011 to June 2013 were chose, all patients were given non-limiting total knee prosthesis. Results The operative time was (91 ± 11 ) min, operative blood loss was (350 ± 45 ) ml ; only one patient had a little black cut edge phenomenon. All patients were followed up for 6 weeks to 1 year. Com- pared the knee flexion and HSS scores before and after, the differences was significant ( P 〈 0. 05 ). Conclusions Non- limiting total knee prosthesis in therapy of stiff knee is satisfactory and effective.
关 键 词:非限制型全膝关节假体 僵直型膝关节 手术