检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]西安高压电器研究院有限责任公司,陕西西安710077 [2]宿迁电力设计院有限公司,江苏宿迁223800
出 处:《电力电容器与无功补偿》2015年第3期45-48,共4页Power Capacitor & Reactive Power Compensation
摘 要:自愈式低压并联电力电容器普遍存在着早期失效损坏现象,其中使用不当也是主要原因。通过案例分析认为,耐过电流能力差、电容量容易衰减是自愈式电容器的弱点,将自愈式低压并联电力电容器直接应用于滤波器中存在一定的危害性,对于要求电容量稳定的滤波器来说,选用非自愈式电容器更为合适,如果要选择自愈式电容器,也应该是符合滤波要求设计的自愈式滤波电容器。Self-healing type low voltage shunt power capacitor generally exists such phenomena as early failure and damage and improper use is also the main reason. It is thought through case analysis that lower over current withstand ability and easy attenuation of capacitance are the weak point of the self- healing type capacitor. There are certain dangers when it is used in the fiher directly, so, to meet the stable capacitance requirement of the filter, choose non self-healing capacitor is more suitable to. The self- healing capacitor, in case of selection, shall be the one complying with the filtering design requirement.