核电厂DCS安全级应用软件的集成测试方法  被引量:1

Software Integration Test for DCS Safety Related System of Nuclear Power Plant

在线阅读下载全文

作  者:徐展 夏丹阳 

机构地区:[1]中核控制系统工程有限公司,北京100176

出  处:《自动化博览》2015年第6期103-105,共3页Automation Panorama1

摘  要:核电厂DCS安全级系统是整个DCS系统的重要组成部分,确保核电厂DCS安全级系统应用软件的安全可靠性是至关重要的,软件验证和确认活动给核电厂安全可靠性提供了重要保障,这其中包括一些相关测试活动,软件集成测试是验证和确认活动的重要环节。本文遵循标准IEEE-1012软件验证与确认,针对安全级平台Tricon系统,给出了一套完整的软件集成测试方法。The safety-level system is the most important part of the whole distributed control system (DCS) in nuclear power plant. It' s important to ensure the safety and reliability of safety-level system application software for nuclear power plant. Software verification and validation provide the important protection for the safety and reliability of nuclear power plant, which include several related test activities. Software integration test is an important part of verification and validation activities. A useful and powerful method of the software integration test on Tricon system for safety related system is given in this article based on IEEE standard 1012 software verification and validation.

关 键 词:软件集成测试 验证和确认 DCS安全级应用软件 

分 类 号:TM623.8[电气工程—电力系统及自动化]

 