测量数MA脉冲电流的探头设计与标定  被引量:6

Design and calibration of B-dot monitor for several mega-ampere current measurement

在线阅读下载全文

作  者:卫兵[1] 卿燕玲[1] 丰树平[1] 傅贞[1] 任济[1] 计策[1] 但加坤 夏明鹤[1] 王勐[1] 

机构地区:[1]中国工程物理研究院流体物理研究所,脉冲功率科学与技术重点实验室,四川绵阳621900

出  处:《强激光与粒子束》2015年第7期228-233,共6页High Power Laser and Particle Beams

基  金:国家自然科学基金项目(1135007)

摘  要:为获得聚龙一号装置负载区电流,设计了测量探头,通过频响测试得到探头的频率上限为51.7MHz;针对标定装置的逼真性进行了分析,实验结果表明,负载区电流探头的灵敏度在误差范围内不受柱孔盘旋面的影响。通过标定结果的外推分析可知:外推是否可靠是由探头能否满足相应测量的工作条件决定,而不是受外推的数量级限制。通过探头测量范围的分析及相应干扰实验,认为标定满足测试需求。实测结果表明负载区电流与磁绝缘传输线电流的测量结果自洽。Differential output current loops (B dot probes) were designed and calibrated to derive inner MITL current in the PTS facility. The B dots' upper limiting frequency was 51.7 MHz in frequency response experiments, which was satisfactory for current measurement in our experiments. The Bdots were calibrated using a radial transmission line that was driven by an azi muthally symmetric current pulse. And then the Bdots were calibrated using a radial transmission line with a post hole convolute feeding structure. The result indicates that the sensitivity of B dots are consistent in the two calibration systems. The interference test and experiments with variable peak currents were performed to focus on B dot linearity, and insulation, pressure exerted by magnetic fields, energy absorbing and related temperature rise of B dot were analyzed in order to assess the validity of Bdot cali bration. The results imply that the B dots are valid for several mega ampere current measurements. Also, it shows that outer MITL current and inner MITL current are self consistent in PTS experiment.

关 键 词:脉冲电流 测量 磁绝缘传输线 标定 

分 类 号:TM835.4[电气工程—高电压与绝缘技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象