Plaques of Nonstenotic Basilar Arteries with Isolated Pontine Infarction on Three-dimensional High Isotropic Resolution Magnetic Resonance Imaging  被引量:11

Plaques of Nonstenotic Basilar Arteries with Isolated Pontine Infarction on Three-dimensional High Isotropic Resolution Magnetic Resonance Imaging

在线阅读下载全文

作  者:Xian-Jin Zhu Wei-Jian Jiang Lei Liu Li-Bin Hu Wu Wang Zun-Jing Liu 

机构地区:[1]Department of Radiology, China-Japan Friendship Hospital, Beijing 100029, China [2]Department of New Era Stroke Care and Research Institute, The Second Artillery'Geneial HospiiaI-People's Liberation Army, Beijing 100088, China [3]Department of Neurology, China-Japan Friendship Hospital, Beijing 100029, China

出  处:《Chinese Medical Journal》2015年第11期1433-1437,共5页中华医学杂志(英文版)

基  金:This study was supported by grants from China- Japan Friendship Hospital Youth Science and Technology Excellence Project (No. 2014-QNYC-A-04), National Natural Science Foundation of China (No. 81173595, No. 30670731, No. 81070925 and No. 81471767), and National Basic Research Program (973 Program) of China (No. 2013CB733805).

摘  要:Background: There are few studies for evaluating plaque characteristics of nonstenotic basilar arteries (BA). Our aim was to determine entire BA plaques with a three-dimensional volumetric isotropic turbo spin-echo acquisition (VISTA) and investigate the differences between the patients with and without isolated pontine infarction (IPI). Methods: Twenty-four consecutive symptomatic patients with nonstenotic BA on time of flight magnetic resonance angiography (TOF MRA) were enrolled from China-Japan Friendship Hospital between January 2014 and December 2014. BA was classified as "normal" or "irregular" based on TOF MRA, and "normal wall", "slight wall-thickening", and "plaque" based on three-dimensional VISTA images. Outcomes from MRA and VISTA were compared. Patients were categorized as IPI and non-lPl groups based on the diffusion-weighted imaging. Clinical and plaque characteristics were compared between the two groups. Results: A total of 1024 image slices including 311 (30.37%) plaque slices, 427 (41.70%) slight wall-thickening slices, and 286 (27.93%) normal wall slices for the entire BA from 23 patients were finally included for analysis. VISTA images detected plaques in all the 9 (100%) irregular MRA patients and 7 of 14 (50%) normal MRA patients. IPl was found in 11 (47.83%) patients. Compared to non-IPI group, the IPI group had a higher percentage of plaque slices (P = 0.001 ) and lower percentage of normal wall slices (P = 0.014) than non-IPl group. Conclusions: Three-dimensional V1STA images enable detection of BA plaques not visualized by MRA. BA plaques could be found in both the IPl and non-IPl group. However, IPI group showed plaques more extensively in BA than the non-IPI group.Background: There are few studies for evaluating plaque characteristics of nonstenotic basilar arteries (BA). Our aim was to determine entire BA plaques with a three-dimensional volumetric isotropic turbo spin-echo acquisition (VISTA) and investigate the differences between the patients with and without isolated pontine infarction (IPI). Methods: Twenty-four consecutive symptomatic patients with nonstenotic BA on time of flight magnetic resonance angiography (TOF MRA) were enrolled from China-Japan Friendship Hospital between January 2014 and December 2014. BA was classified as "normal" or "irregular" based on TOF MRA, and "normal wall", "slight wall-thickening", and "plaque" based on three-dimensional VISTA images. Outcomes from MRA and VISTA were compared. Patients were categorized as IPI and non-lPl groups based on the diffusion-weighted imaging. Clinical and plaque characteristics were compared between the two groups. Results: A total of 1024 image slices including 311 (30.37%) plaque slices, 427 (41.70%) slight wall-thickening slices, and 286 (27.93%) normal wall slices for the entire BA from 23 patients were finally included for analysis. VISTA images detected plaques in all the 9 (100%) irregular MRA patients and 7 of 14 (50%) normal MRA patients. IPl was found in 11 (47.83%) patients. Compared to non-IPI group, the IPI group had a higher percentage of plaque slices (P = 0.001 ) and lower percentage of normal wall slices (P = 0.014) than non-IPl group. Conclusions: Three-dimensional V1STA images enable detection of BA plaques not visualized by MRA. BA plaques could be found in both the IPl and non-IPl group. However, IPI group showed plaques more extensively in BA than the non-IPI group.

关 键 词:Atherosclerosis Basilar Artery High Resolution Isolated Pontine Infarction Magnetic Resonance Imaging 

分 类 号:O482.531[理学—固体物理] Q149[理学—物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象