单眼深度知觉对调节反应的影响  被引量:1

Effect of monocular depth perception on accommodative response

在线阅读下载全文

作  者:陈茹茹[1] 吕帆[1] 王瑞珺[1] 保金华[1] 乐融融[1] 

机构地区:[1]温州医科大学眼视光学院,325027

出  处:《中华实验眼科杂志》2015年第6期519-524,共6页Chinese Journal Of Experimental Ophthalmology

基  金:国家重点基础研究发展计划项目(2011CB504601)

摘  要:背景平面画面中有多种视觉线索构成深度或距离感知信息,但目前尚不清楚究竟是哪些深度线索对人眼的调节起主要作用,以及注视距离的不同是否使这种影响存在差异。目的研究不同距离的单眼空间深度感知对人眼调节反应的影响,分析线性透视和大小知觉恒常性深度线索对调节反应水平及波动幅度所起的作用。方法运用FLASH软件设计4组视标,视标1为静止环形图案;视标2包含大小知觉恒常性深度线索,动态表现从远至近或从近至远的环形图案;视标3包含线性透视和大小知觉恒常性2种深度线索,动态表现从远至近及从近至远的连续变化的车行轨迹;视标4去除线性透视深度线索,仅表现视标3中车的大小的动态变化。纳入26名22~26岁的受试者,球镜度数平均为(一4.06±1.99)D,柱镜度数平均为(-0.38±0.41)D,在矫正视力下单眼分别注视50cm和33.3cm的视标,采用Grand Seiko WAM-5500近红外开放视野自动验光仪,以5次/s的调节反应记录方式,全程记录受试者在注视变化过程中的调节反应及调节微波动。结果在50cm的注视距离下,由大小知觉恒常性和线性透视共同作用时(注视视标3),由近处的距离感知引起的调节反应值为(1.52±0.46)D,远处为(1.37±0.46)D,两者间差异有统计学意义(P=0.016);由大小知觉恒常性独立作用时(注视视标4),大车的调节反应值为(1.43±O.35)D,小车为(1.43±O.36)D,差异无统计学意义(P=0.467)。在33.3cm的注视距离下,由大小知觉恒常性和线性透视共同作用时(注视视表3),由近处的距离感知引起的调节反应均值为(2.40±0.53)D,远处为(2.35±0.51)D,差异无统计学意义(P=0.379);由大小知觉恒常性独立作用时(注视视标4),大车的调节反应均值为(2.38±0.48)D,小车为�Background Different depthes or distances are prompted with many visual cues on the flat screen. Which kind of depth cues plays a major role in the accommodation of human eyes,in addition,whether this effect exists in the different distance are still below understood. Objective This study was to research the effect of the monocular space depth perception on accommodative response at different distances, and to analyze the effect of linear perspective and size-constancy perceptual depth cues on the level and amplitude of accommodative fluctation. Methods Four groups of visual targets were designed by FLASH software and placed at the front of eyes with the distance of 50 cm or 33.3 cm,representing static change from far to near and dynamic change from far to near,from near to far respectively. Twenty-six healthy volunteers aged 22-26 years were included in this study, with the spherical power of (-4.06± 1.99) D and cylindrical power of (-0.38±0.41) D under the informed consent. The accommodative response and accommodative fluctuations during monocularly watching the targets were recorded at 5 times/second by Grand Seiko WAM 5500 automatic infrared refractor. This study was approved by Ethic Committee of Wenzhou Medical University,and written informed consent was obtained from each subject before entering the study group. Results At the distance of 50 cm,the accommodative response caused by the depth perception of near was (1.52±0.46) D,the one of distance was (1.37±0.46) D,with a significant difference of O. 15 D under the combined effect of linear perspective and size-constancy ( P = 0. 016). The accommodative response caused by the depth perception of big car was ( 1.43 ± 0.35 ) D, and the one of small car was ( 1.43 ±0. 36) D, without statistically significant difference under the effect of size-constancy alone ( P = 0. 467 ). At the distance of 33.3 cm, the accommodative response caused by the depth perception of near was (2.40±0.53)D,and the one of distance was (2.3

关 键 词:眼调节/生理 线索  空间深度知觉/生理 心理物理学 视觉识别模式/生理 

分 类 号:R339.14[医药卫生—人体生理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象