北京燃气管道牺牲阳极服役参数测试及变化规律  被引量:6

Test and Change Law of the Service Parameters of Magnesium Sacrificial Anodes of Beijing Gas Pipelines

在线阅读下载全文

作  者:李夏喜[1] 杜艳霞[2] 段蔚[1] 唐德志[2] 王庆余[1] 褚大军 

机构地区:[1]北京市燃气集团有限责任公司,北京100011 [2]北京科技大学新材料技术研究院,北京100083

出  处:《腐蚀与防护》2015年第3期263-267,271,共6页Corrosion & Protection

基  金:北京市燃气集团有限责任公司科研项目<运行10a以上牺牲阳极服役行为和剩余寿命预测研究>

摘  要:为了掌握北京燃气管道牺牲阳极阴极保护系统的运行状况,对20处管段共27支镁合金牺牲阳极的服役参数进行了现场测试,并开挖取样进行实验室分析。结合现场测试与实验室测试结果,分析得到了不同情况下牺牲阳极消耗状况及服役参数的变化规律,可为燃气管道牺牲阳极阴保系统的维护管理及寿命预测提供参考。In this work, field tests and laboratory measurements were conducted to investigate the performance of magnesium sacrificial anode cathodic protection (CP) system of Beijing Gas Group Company Limited. Based on the results of field tests and laboratory measurements, the factors affecting the performance of magnesium sacrificial anodes were analyzed, which may provide important reference for the operation maintaining and life prediction of sacrificial anode CP system of city gas pipelines.

关 键 词:镁牺牲阳极 阴极保护 服役性能 现场测试 消耗速率 

分 类 号:TG174[金属学及工艺—金属表面处理] TE8[金属学及工艺—金属学]

 