内镜超声引导下胆道穿刺引流技术的应用  被引量:5

Application of endoscopic ultrasound guided biliary drainage technology

在线阅读下载全文

作  者:王晟[1] 孙思予[1] 刘香[1] 葛楠[1] 郭瑾陶[1] 刘文[1] 王树朋[1] 胡金龙[1] 

机构地区:[1]中国医科大学附属盛京医院内镜中心,沈阳110004

出  处:《中华消化内镜杂志》2015年第6期378-381,共4页Chinese Journal of Digestive Endoscopy

摘  要:目的评价经内镜逆行胰胆管造影术(ERCP)治疗失败的胆道梗阻患者行内镜超声引导下胆道穿刺引流(EUS-BD)的疗效及安全性。方法回顾性总结2014年8月至2015年1月期间,8例ERCP引流失败后行EUS-BD的胆道梗阻患者的临床资料,分析EUSBD的疗效及并发症发生情况。结果8例均操作成功,于胆道与消化道之间顺利放置全覆膜金属支架,解除胆道梗阻,且术后恢复良好,无明显并发症发生。结论EUS—BD是一种安全、有效的胆道引流方式,可以作为ERCP失败后的备用治疗方案。Objective To evaluate the effectiveness and safety of endoscopic ultrasound guided bili- ary drainage (EUS-BD)technology for biliary obstruction where ERCP( endoscopic retrograde cholangiopan- creatography) failed. Methods EUS-BD was performed on 8 patients with biliary obstruction after failure of ERCP. Clinical data were collected, and effectiveness and complications of EUS-BD were analysed. Results Procedures were performed successfully on 8 patients. Full covered metallic stentts were placed be- tween biliary and digestive tract to relieve biliary obstruction, and all patients recovered with no complica- tions. Conclusion EUS-BD is a safe and effective way for the biliary drainage, and it can be used as a standby treatment after the failure of ERCP.

关 键 词:腔内超声检查 内镜胆管引流 穿刺术 金属支架 

分 类 号:R657.4[医药卫生—外科学]

 