太阳能空气集热及转轮除湿/加湿混合系统冬季供暖分析  被引量:4

EXPERIMENTAL INVESTIGATION OF SOLAR HEATING AND HUMIDIFICATION SYSTEM WITH DESICCANT ROTOR IN WINTER

在线阅读下载全文

作  者:何海斌[1] 李勇[1] 代彦军[1] 王如竹[1] 

机构地区:[1]上海交通大学制冷与低温工程研究所,上海200240

出  处:《太阳能学报》2015年第7期1690-1696,共7页Acta Energiae Solaris Sinica

基  金:国家自然科学基金(51076097)

摘  要:针对一种太阳能空气集热及转轮除湿混合系统,在上海冬季典型低温干燥气候条件下对供暖运行进行研究,实验测试直接供暖,加湿供暖和热泵效应供暖3种不同供暖模式的供暖效果,分析冬季太阳辐射对空气集热温度的影响,不同环境温湿度下3种工作模式对供暖温湿度的影响以及加湿供暖与热泵效应供暖模式中回风对供暖温湿度的影响。实验结果表明,3种模式下送风温度随再生温度升高而升高,送风湿度取决于处理风入口湿度和再生温度的大小,系统在采用回风的加湿供暖模式下,平均送风湿度达到12g/(kg干空气),送风温度为26—37℃,冬季全天大部分时间能有效满足室内送风的温湿度要求。A solar air heating system, which integrates the desiccant humidifier, was installed, tested and analyzed technologies of evacuated tube solar air collector and rotary in winter weather conditions of Shanghai. Three operation modes are implemented, namely, direct solar heating mode, solar heating with desiccant humidification mode, and heat pump effect heating mode. The objective of this paper is to test the performance of the three modes, the effect of solar radiation on regeneration temperature and the effect of regeneration temperature on the supply air temperature and humidity under different operating conditions. Besides, the effect of return air on the supply air temperature and humidity was also tested under dry and cold weather in winter. The experiment results showed that the temperature of supply air increased with the regeneration temperature, but the supply air humidity depends on the humidity ratio of process air inlet and regeneration temperature. Additionally, the solar heating with desiccant humidification mode with return air is the best way of winter heating and humidification. Only this working mode can meet the requirements of supply air condition in winter season of Shanghai

关 键 词:转轮除湿 加湿 供暖 加湿供暖 空气调节 

分 类 号:TK513.5[动力工程及工程热物理—热能工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象