作 者:马超豪 李琦[1] 罗天友[1] 王卓楠[1] 史丹丹[1]
机构地区:[1]重庆医科大学附属第一医院放射科,重庆400016
出 处:《中国医学影像技术》2015年第7期1053-1057,共5页Chinese Journal of Medical Imaging Technology
基 金:国家临床重点专科建设项目(国卫办医涵[2013]544号)
摘 要:目的探讨能谱CT检测中央型肺癌周围肺组织灌注缺损的能力,并分析灌注缺损与中央肺动脉受侵的关系。方法对30例中央型肺癌患者行宝石能谱成像(GSI)模式增强扫描,经图像后处理获得70keV的单能CTA图像及碘基物质图像。于单能CTA图像上分析中央肺动脉受侵情况、以5分法进行评分;于碘基物质图像上测量并比较癌周肺组织与对侧相应区域正常肺组织的碘含量,计算癌周肺组织碘含量下降率并分析其与中央肺动脉受侵评分的相关性。结果30例中央型肺癌患者中,共检出受侵中央肺动脉66支,受侵评分为(2.21±0.58)分。癌周肺组织碘含量[(0.73±0.38)mg/ml]明显低于对侧相应区域正常肺组织碘含量[(1.45±0.57)mg/ml],两者差异有统计学意义(t=-9.23,P〈0.001);癌周肺组织碘含量下降率范围为14.5%~87.2%,中位数为52.9%,与中央肺动脉受侵评分呈明显正相关(r=0.94,P〈0.001)。结论能谱CT不仅能够检测出中央型肺癌周围肺组织灌注缺损,还能量化评价中央型肺癌中央肺动脉不同程度受侵所致癌周肺组织灌注缺损情况。Objective To evaluate the capability of spectral CT imaging in detecting the lung perfusion defects induced by central lung cancer,and to compare the correlation between the lung perfusion defects and the involvement of central pulmonary artery from central lung cancer.Methods Thirty patients with central lung cancer underwent enhanced CT with gemstone spectral imaging(GSI)mode.Then the monochromatic CTA imaging and iodine-based material decomposition imaging were obtained.On the monochromatic CTA images,scoring of five grades was applied to evaluate the central pulmonary artery involvement.On the iodine-based material decomposition images,iodine concentration were measured and compared between periphery of the central lung cancer and corresponding area of the contralateral normal lung,then the descent rate of iodine concentration in periphery of the central lung cancer was calculated.The correlation between the score of central pulmonary artery involvement and the descent rate of iodine concentration was analyzed.Results In thirty patients with central lung cancer,there were 66 central arteries involvement,the score was 2.21±0.58.The iodine concentration in periphery of the central lung cancer was significantly lower than that in corresponding area of the contralateral normal lung([0.73±0.38]mg/ml vs[1.45±0.57]mg/ml,t=-9.23,P〈0.001).The range of the descent rate of iodine concentration in periphery of the central lung cancer was from 14.5%to 87.2%(median 52.9%).There was a significantly positive correlation between the score of central artery involvement and the descent rate of iodine concentration(r=0.94,P〈0.001).Conclusion Spectral CT imaging not only can be used to detect,but also to evaluate quantitatively the lung perfusion defects induced by the different degree of central pulmonary artery involvement from central lung cancer.
关 键 词:肺肿瘤 体层摄影术 X线计算机 宝石能谱成像 灌注成像 肺动脉
分 类 号:R814.42[医药卫生—影像医学与核医学] R734.2[医药卫生—放射医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.116.15.98