自动、半自动与手动方法肝体积测量准确性的比较:Meta分析研究  被引量:2

The comparison study of accuracy of automatic, semi-automatic and manual liver volumetry: result of Metaanalysis

在线阅读下载全文

作  者:庞丽华[1] 龙淼淼[1] 牟玲[2] 李艳艳[1] 于文娟[1] 刘铁[1] 沈文[1] 

机构地区:[1]天津市第一中心医院放射科,天津300192 [2]日照市人民医院放射科

出  处:《国际医学放射学杂志》2015年第4期313-317,共5页International Journal of Medical Radiology

基  金:天津市卫生局科技基金面上项目(2012KY07)

摘  要:目的采用循证医学Meta分析方法比较自动、半自动和手动方法测量肝体积的准确性。方法在Cochrane图书馆、Medline、Embase、中国生物医学文摘数据库和全文数据库(Springer、OVID、万方数据库等)检索CT或MRI测量全肝体积的中英文文献,根据纳入文献中所记录的手动、半自动或自动方法分组,采用统计分析软件R的Meta软件包对提取信息进行统计分析。结果共纳入16篇文献,36项研究,315例病人。手动法、半自动法和自动法三组影像方法测量肝体积和实际肝体积差异均无统计学意义,其中手动法影像测量和实际肝体积的加权均数差值为12.098 m L(95%CI:-26.392~50.588 m L),P=0.538;半自动法为26.186 m L(95%CI:-29.842~82.213 m L),P=0.360;自动法为57.144 m L(95%CI:-10.770~125.059 m L),P=0.099。各组汇总结果之间差异也无统计学意义(Q=0.15,P=0.930)。结论手动、半自动及自动方法都是准确的肝体积影像测量方法,自动、半自动方法可以大大提高测量效率,具有很好的推广价值。Objective To compare the accuracies of manual, semi-atuomatic and automatic whole liver volumetry with Meta-analysis. Methods Cochrane library, abstract databases(MEDLINE, EMBASE, and China biology medicine disc) and full text databases(Springer, OVID, CNKI, Wan Fang, et al) were searched for published papers on whole liver volumetry with CT or MR modality. Eligible papers were grouped according to the volumetry method(manual, semi-automatic and automatic) and evaluated for quality. With Meta-analysis package Meta of R software, group-wise Meta-analysis and comparison were performed. Results Sixteen articles including 315 patients met the inclusion criteria. There was no heterogeneity among included studies and there were no significant differences between radiologically estimated and true liver volumes of every group. The weighted mean difference was 12.098 m L(95%CI:-26.392~50.588 m L) in the manual group(P=0.538), 26.186 m L(95%CI:-29.842~82.213 m L) in the semi-automatic group(P=0.360) and 57.144 m L(95%CI:-10.770~125.059 m L) in the automatic group(P=0.099). The pooled results did not significantly differ among the three groups(Q=0.15,P =0.930). Conclusion The manual, semi-automatic and automatic liver volumetry are comparable in accuracy while the semi-automatic and automatic volumetry could greatly shorten measuring time, which are worthy of recommendation in clinical setting.

关 键 词:肝体积 手动法 半自动法 自动法 META分析 

分 类 号:R195.1[医药卫生—卫生统计学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象