检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Mengpei Chen Shiqin Jiang Lu Bing Chen Zhao Birgit Hailer Dietrich Gr nemeyer Peter Van Leeuwen
机构地区:[1]School of Electronics and Information Engineering, Tongji University [2]Department of Internal Medicine, Philippusstift, University Witten/Herdecke [3]Faculty of Health, Gro¨ nemeyer Institute for Microtherapy,University Witten/Herdecke
出 处:《Science Bulletin》2015年第14期1235-1240,共6页科学通报(英文版)
基 金:supported by the National Natural Science Foundation of China(60771030);the National HighTechnology Research and Development Program of China(2008AA02Z308);the Shanghai Science and Technology Development Foundation(08JC1421800);Shanghai Leading Academic Discipline Project(B004);the Open Project of State Key Laboratory of Function Materials for Information(Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences)
摘 要:Cardiac current source reconstruction is investigated by a fast greedy sparse(FGS) method applied to simulated and real magnetocardiography(MCG) data measured using 61-channel superconducting quantum interference device. The approach reduces the size of the lead field matrix based on a priori knowledge of dipolar magnetic field map. Consequently, the computational demands and the accuracy of sparse source reconstruction are improved simultaneously. The simulation results demonstrate that the FGS method is capable of reconstructing sparse equivalent current sources using the magnetic field data generated by a single current source with varying orientation or multiple current sources generated randomly. In addition, we analyze the cardiac current source reconstructed with real MCG data at typical instants and discuss the electrical excitation conduction during the QRS complex based on moving sparse source imaging.Cardiac current source reconstruction is investigated by a fast greedy sparse (FGS) method applied to simulated and real magnetocardiography (MCG) data measured using 61-channel superconducting quantum interference device. The approach reduces the size of the lead field matrix based on a priori knowledge of dipolar magnetic field map. Consequently, the computational demands and the accuracy of sparse source reconstruction are improved simultaneously. The simulation results demonstrate that the FGS method is capable of recon- structing sparse equivalent current sources using the magnetic field data generated by a single current source with varying orientation or multiple current sources generated randomly. In addition, we analyze the cardiac current source reconstructed with real MCG data at typical instants and discuss the electrical excitation conduction during the QRS complex based on moving sparse source imaging.
关 键 词:Magnetocardiography (MCG) Sparsedecomposition Current source reconstruction Cardiac electrical activity Signal processing
分 类 号:TN911.7[电子电信—通信与信息系统]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.85