广州地铁五号线车辆蓄电池欠压保护电路分析及改进方案  被引量:1

Analysis and Improvement Scheme for Battery Under-Voltage Protection of Guangzhou Metro Line 5 Vehicles

在线阅读下载全文

作  者:韦义林 

机构地区:[1]广州市地下铁道总公司,广东广州510380

出  处:《机电工程技术》2015年第7期191-194,共4页Mechanical & Electrical Engineering Technology

摘  要:广州地铁五号线列车在进行蓄电池通电时长试验中,出现了蓄电池欠压保护电路失效的现象。通过对列车蓄电池欠压保护电路设计原理进行分析,确定失效原因为欠压继电器选型错误及欠压保护电路设计缺陷。针对此情况,提出两种改进方案,优化城轨车辆蓄电池欠压保护的设计,避免列车蓄电池出现过放电故障。Under-voltage protection circuit of battery fail during the battery electricity duration experiment for Guangzhou metro line 5vehicle. This paper analyzes design principle of the train battery under-voltage protection circuit, which confirming the cause of failure are that under-voltage relay selection error and under-voltage protection circuit design flaws. Aimed at the situation, we put forward two kinds of improvement schemes to optimize the battery under-voltage protection design of urban rail vehicle, which could help avoid the fault of train battery over discharge.

关 键 词:欠压保护 欠压继电器 过放电 

分 类 号:U264.7[机械工程—车辆工程]

 