690t/hCFB锅炉运行中参数偏离设计值的解决措施  被引量:1

690t/h CFB boiler parameters deviate from the Designed value measures during operation

在线阅读下载全文

作  者:张兴阳 

机构地区:[1]神华亿利能源有限责任公司,内蒙古鄂尔多斯014300

出  处:《神华科技》2015年第4期61-64,共4页Shenhua Science and Technology

摘  要:神华亿利能源公司690t/h CFB锅炉自投产运行以来,普遍存在床温高、分离器分离效率低、SO2排放值高、飞灰浓度高、空预器漏风、风机耗电量高、含氧量和排烟温度高、锅炉热效率低,锅炉主要运行参数偏离设计值的问题。本文论述了对690t/h CFB锅炉在设备改造和运行调整方面采取的措施及取得的效果,为其它运行的CFB锅炉存在的同类问题解决提供了可借鉴的经验。Shen hua yi li energy co.,ltd 690t/h CFB boiler has since put into operation, common bed tempera-ture high, the separating efficiency of separator is low, high levels of SO2 emissions, fly ash concentration high, air leakage of air preheater, fan power consumption, high oxygen content and high exhaust gas tempera-ture, the boiler thermal efficiency is low, the main operating parameters of the boiler from the design value problem. This paper discusses to adopt 690t/h CFB boiler in the reform and operation of the equipment ad-justment measures and the results, and provide reference to solve similar problems for other operation of CFB boiler.

关 键 词:CFB锅炉参数 偏离设计值 解决措施 

分 类 号:TK22[动力工程及工程热物理—动力机械及工程]

 