摘  要:阻尼器是核电厂管道和设备安全的重要保护装置,其功能能否正常实现与其型号和安装长度设定参数有着密不可分的关系。从设计依据、流程、功能实现等几个方面详细描述了阻尼器校核程序研究的整个过程,并对计算和判断方法进行了介绍,最后以工程实例的方式对阻尼器校核程序的使用进行了说明。程序已在多个核电工程项目上进行了应用,从工程设计和运行实践证明,程序运行稳定、操作简单、计算准确,显著提高了工作效率。The snubber is an important device to protect the safety of the equipment and pipe in nuclear power plant. The realization of its function depends on the accurate selection of the type and on the accurate setting of installation parameter. The article introduces the development of this program from several aspects, such as design basis, flow, realization of function, and describes the method of calculation and estimation .How to use this program is explained though an engineering example. The program has been applied in multiple nuclear power projects. The practice proved the program is running stable,easy to operate and the calculation result is accurate. Using this program, The designer can greatly improve the work efficiency.