AxSYM和Architect i1000 sr系统测定地高辛血药浓度的比较  被引量:3

Comparison of Ax SYM and Architect i1000 sr system for determination of digoxin concentration

在线阅读下载全文

作  者:秦英[1] 石秀锦[1] 林阳[1] 顾虹[2] 王海燕[1] 李骁[1] 周洋[1] 白玉国[1] 郑青敏[1] 

机构地区:[1]首都医科大学附属北京安贞医院药事部,北京100029 [2]首都医科大学附属北京安贞医院小儿心脏中心,北京100029

出  处:《中国药物应用与监测》2015年第4期212-214,共3页Chinese Journal of Drug Application and Monitoring

摘  要:目的:研究Ax SYM和Architect i1000 sr系统测定地高辛血药浓度结果相关性,并比较其对内源性地高辛样免疫活性物质的敏感性。方法:同时采用Ax SYM和Architect i1000 sr系统测定100例患者的地高辛血药浓度,以Ax SYM的测定值为X,Architect i1000 sr的测定值为Y,进行线性回归,评价其相关性。同时采用两个系统测定56例未服用地高辛患者的表观地高辛血药浓度,比较其对内源性地高辛样免疫活性物质的敏感性。结果:Architect i1000 sr的测定值小于Ax SYM的测定值,两者相关性良好(r=0.931),回归方程为Y=0.746 X–0.315 8。56例未服用地高辛患者Architect i1000 sr测得的表观地高辛浓度均为0,Ax SYM测定时28例患者表观地高辛浓度大于0.3 ng·m L-1。结论:尽管Ax SYM和Architect i1000 sr系统测定地高辛血药浓度结果相关性良好,然而Architect i1000 sr系统的测定值偏低,进行方法间切换时,药师和医师应予以注意。Architect i1000 sr系统对内源性地高辛样免疫活性物质的敏感性低于Ax SYM系统。Objective: To assess the correlation between the serum digoxin levels measured by AxSYM and Architect il000 sr systems and compare the two systems with respect to interference from digoxin-like immunoreactive substances. Methods: Serum digoxin levels of 100 patients were determined by AxSYM and Architect i1000 sr systems. Regression analysis was performed to evaluate the correlation. The interference of digoxin-like immunoreactive substances on both assays was investigated in samples from 56 patients who were not taking digoxin. Results: Serum digoxin levels determined by Architect il000 sr system were significantly lower than those of AxSYM system. Concordance analysis revealed a positive and statistically significant correlation coefficient (r = 0.931). The equation was Y = 0.746 X- 0.315 8. The apparent digoxin concentrations were 0 in all of the non digoxin-treated patients when measured with Architect i1000 sr system, while the apparent digoxin concentrations of 28 non digoxin-treated patients were greater than 0.3 ng.mL-1 when measured with AxSYM system. Conclusion: The correlation between the serum digoxin levels from both assays is well. However, values obtained by Architect il000 sr system are lower than those of AxSYM system. Susceptibility to interference from digoxin-like immunoreactive substances of AxSYM system was significantly greater than that of Architect i1000 sr system.

关 键 词:地高辛 血药浓度 AX SYM ARCHITECT i1000 SR 

分 类 号:R927.2[医药卫生—药学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象