Flexible reduced field of view magnetic resonance imaging based on single-shot spatiotemporally encoded technique  被引量:1

Flexible reduced field of view magnetic resonance imaging based on single-shot spatiotemporally encoded technique

在线阅读下载全文

作  者:李敬 蔡聪波 陈林 陈颖 屈小波 蔡淑惠 

机构地区:[1]Department of Electronics Science,Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance,Xiamen University [2]Department of Communication Engineering,Xiamen University [3]Center for Brain Imaging Science and Technology,Zhejiang University

出  处:《Chinese Physics B》2015年第10期629-637,共9页中国物理B(英文版)

基  金:Project supported by the National Natural Science Foundation of China(Grant Nos.11474236,81171331,and U1232212)

摘  要:In many ultrafast imaging applications, the reduced field-of-view(r FOV) technique is often used to enhance the spatial resolution and field inhomogeneity immunity of the images. The stationary-phase characteristic of the spatiotemporallyencoded(SPEN) method offers an inherent applicability to r FOV imaging. In this study, a flexible r FOV imaging method is presented and the superiority of the SPEN approach in r FOV imaging is demonstrated. The proposed method is validated with phantom and in vivo rat experiments, including cardiac imaging and contrast-enhanced perfusion imaging. For comparison, the echo planar imaging(EPI) experiments with orthogonal RF excitation are also performed. The results show that the signal-to-noise ratios of the images acquired by the proposed method can be higher than those obtained with the r FOV EPI. Moreover, the proposed method shows better performance in the cardiac imaging and perfusion imaging of rat kidney, and it can scan one or more regions of interest(ROIs) with high spatial resolution in a single shot. It might be a favorable solution to ultrafast imaging applications in cases with severe susceptibility heterogeneities, such as cardiac imaging and perfusion imaging. Furthermore, it might be promising in applications with separate ROIs, such as mammary and limb imaging.In many ultrafast imaging applications, the reduced field-of-view(r FOV) technique is often used to enhance the spatial resolution and field inhomogeneity immunity of the images. The stationary-phase characteristic of the spatiotemporallyencoded(SPEN) method offers an inherent applicability to r FOV imaging. In this study, a flexible r FOV imaging method is presented and the superiority of the SPEN approach in r FOV imaging is demonstrated. The proposed method is validated with phantom and in vivo rat experiments, including cardiac imaging and contrast-enhanced perfusion imaging. For comparison, the echo planar imaging(EPI) experiments with orthogonal RF excitation are also performed. The results show that the signal-to-noise ratios of the images acquired by the proposed method can be higher than those obtained with the r FOV EPI. Moreover, the proposed method shows better performance in the cardiac imaging and perfusion imaging of rat kidney, and it can scan one or more regions of interest(ROIs) with high spatial resolution in a single shot. It might be a favorable solution to ultrafast imaging applications in cases with severe susceptibility heterogeneities, such as cardiac imaging and perfusion imaging. Furthermore, it might be promising in applications with separate ROIs, such as mammary and limb imaging.

关 键 词:magnetic resonance imaging spatiotemporal encoding single shot reduced field-of-view 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术] R445.2[自动化与计算机技术—计算机科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象