检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津大学电力系统仿真控制教育部重点实验室,天津300072 [2]天津大学电气工程系,天津300072 [3]辽宁省电力公司,辽宁沈阳110006
出 处:《电源技术》2015年第9期1965-1967,1971,共4页Chinese Journal of Power Sources
摘 要:电力系统故障切除时间对概率不安全指标会产生一定影响。通过数值仿真实验,得出不同故障切除时间对应的功率注入空间动态安全域超平面之间具有近似平行性,并且其距离呈近似线性关系的经验性性质。利用该性质得出包含故障切除时间的扩展动态安全域,并依此提出概率不安全指标的简化算法。WSCC4机11节点系统上的算例表明,采用此种算法,与不考虑故障切除时间变化时相比,计算误差减小41%,计算时间仅增加2%。证明了此种方法具有一定的实用性。The fault clearing time affects the probabilistic insecurity index in power systems. Through the numerical simulation experiment, it's found that the hyperplanes of dynamic security region corresponding to different fault clearing time have the approximately parallel property, and the distance between the hyperplanes is almost linear. With the two nature, an extended dynamic security region including the fault clearing time was got, and the simplified algorithm for the probabilistic insecurity index was found. The examples of WSCC 4-machine 11-node system show that compared with the algorithm which assumes that the fault clearing time is a constant, the error of the algorithm decreases by 41%, and the calculating time increases by 2%. The result proves that the algorithm is practical.
关 键 词:故障切除时间 概率不安全指标 动态安全域 经验性质 简化算法
分 类 号:TM711[电气工程—电力系统及自动化]