作  者:杨懂艳[1] 刘保献[1] 魏强[1] 陈圆圆[1] 

机构地区:[1]北京市环境保护监测中心,北京100048

出  处:《化学研究与应用》2015年第9期1398-1402,共5页Chemical Research and Application

基  金:北京市科委项目(Z121100000312035)资助

摘  要:本文采用四通道采样器,使用Teflon和石英膜对环境空气中的PM2.5样品进行采样,并使用超声振荡-离子色谱法对其中的水溶性离子进行分析。分析结果表明,石英膜和Teflon膜本底结果差异性不大,但石英膜本底离子浓度范围相对较宽。Teflon膜适合于PM2.5质量浓度的测量,石英滤膜更适合于冬季PM2.5水溶性离子的检测分析。Four channel samplers with Quartz and Teflon membranes were used for sampling PM2. 5 and Water-soluble ions were ana-lyzed. The results showed that,there were no obvious differences of background ion concentration between Teflon and Quartz mem-branes,but Quartz showed a relatively wide range concentration of ions. The results also indicated Teflon membranes would be more adapted for the determination of the weight of PM2. 5 ,and Quartz would be more suitable for the determination of water soluble ions in winter.

关 键 词:PM2.5 水溶性离子 超声振荡 离子色谱法 