检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国人民公安大学刑事科学技术学院,北京102623 [2]北京市公安局刑事科学技术研究所,北京100054
出 处:《消防科学与技术》2015年第9期1265-1268,共4页Fire Science and Technology
基 金:公安部技术研究计划项目"火场中汽油燃烧残留物的快速分析研究"(2014JSYJB012)
摘 要:利用红外气体池法分析火灾现场汽油残留物,探索和优化实验条件,获取汽油残留成分的红外特征吸收峰。针对模拟火场燃烧残留物的检验,考察燃烧载体、燃烧时间、汽油的用量等因素对于检验结果的影响。结合实际案例,应用红外气体池法进行检验鉴定,并与常规GC/MS分析手段检验的结果进行比较。研究表明,红外气体池法快捷有效,为火灾现场汽油残留物的检验提供了一种新的研究思路。Residual gasoline on fire scene was analyzed by the method of infrared gas cell. The experimental conditions were explored and optimized, and the infrared absorption characteris- tics of residual components of gasoline were obtained. According to the simulated fire burning residue test,the influence of burn- ing carrier,burning time, the amount of gasoline and other fac- tors on the test results was inspected. With the example of actu- al case, infrared gas cell inspection was used and compared with GC/MS analysis. The research showed that infrared gas cell was an efficient and effective method for testing the residual gasoline on fire scene,which provided us a new research idea.
分 类 号:X928.7[环境科学与工程—安全科学] TU998.12[建筑科学—市政工程]