检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵宁[1] 牛立娜[1,2] 梁玉娇[1] 陈世砚 田鹏飞
机构地区:[1]河北大学质量技术监督学院,河北保定071002 [2]河北省计量监督检测院气体流量实验室,河北石家庄050051
出 处:《河北大学学报(自然科学版)》2015年第5期546-551,共6页Journal of Hebei University(Natural Science Edition)
基 金:国家自然科学基金资助项目(61475041);河北省自然科学基金资助项目(F2015201215);河北省教育厅重点资助项目(ZH2012064);河北省教育厅青年基金资助项目(QN2015216)
摘 要:通过研究智能孔口流量计的工作原理,提出了基于钟罩标准装置的正压校准法和基于标准流量计的负压校准法,分别建立了实验测量系统和数学模型.通过2种校准法的检测实验,对实验结果的不确定度进行了分析评价,并对2种方法进行了比对分析.Based on research of operational principle of intelligent orifice flow-meter, two calibration methods were presented; one was positive pressure method which was based on the bell gas flow standard device, the other was negative pressure method which was based on the standard flow-meter, the measurement systems and mathematical models were established respectively. Through detection experiments of the two calibration methods, the uncertainties of experimental results were analyzed and evaluated, comparative analysis of the two methods were proposed.
分 类 号:TK313[动力工程及工程热物理—热能工程] X830.2[环境科学与工程—环境工程]