GlobalFiler?试剂盒在尸骨鉴定中的应用  被引量:4

Identifi cation of Unknown Corpses Using Global Filer^(TM) Kit

在线阅读下载全文

作  者:任文彦 郝宏蕾 王怀锋[2] 吴微微 苏艳佳 

机构地区:[1]浙江省公安物证鉴定中心浙江省刑事科学技术应用研究重点实验室,杭州310009 [2]浙江警察学院,杭州310053

出  处:《刑事技术》2015年第5期379-381,共3页Forensic Science and Technology

基  金:公安部重点研究计划项目(No.201202ZDYJ007)

摘  要:目的分析Global Filer?试剂盒在白骨化尸体身源认定中的技术性能指标。方法采用硅珠法提取50份尸源认定中的骨骼、牙齿样本DNA,其中三联体亲权鉴定11份,二联体亲权鉴定39份,比较Global Filer?试剂盒和Identifi ler Plus试剂盒检验结果。结果 Global Filer?试剂盒成功检出了50份样本STR分型。11份三联体的尸源认定中,两种试剂盒计算得到的CPI值均能达到10 000以上,但Global Filer?试剂盒得到的累积父权指数(CPI值)更高,其中10份能达到108以上。39份二联体的尸源认定中,Global Filer?试剂盒得到的CPI均能达到10 000以上,而Identifi ler Plus试剂盒得到的CPI值能达到10 000以上的只有30例。而且Global Filer?试剂盒扩增得到21个常染色体,Amel基因座和Y-indel、DYS391的分型信息,其特有的Y-indel和DYS391两个基因座,确保在Amelogenin基因座Y等位基因丢失的样本中,可以成功检出性别基因,防止性别误判。结论 Global Filer?试剂盒扩增可以获得比目前常用的Identifi ler Plus试剂盒更多基因信息,大大提高了身源鉴定中的CPI值,而且可以有效避免Amelogenin基因座Y等位基因丢失时导致的无名尸体性别误判。因此,Globalfi ler试剂盒在白骨化尸体身源认定中具有较高的应用价值。Objective To analyze the performance of GlobalFiler^TM kit testing bones of corpses. Methods Silicon bead method was used to extract DNA from 50 samples of bones and teeth that were all required to determine their source with 11 of them waiting for the triplet and the rest 39 ones the duo paternity testing. The GlobalFiler^TM kit and ldentifiler Plus kit were employed to evaluate their testing competence and cumulative paternity index (CPI) values. Results GlobalFiler^TM kit successfully detected the STR types of the 50 samples. For identification of cadaveric source of the 11 triplet cases, although both kits showed to have CPI values greater than 10,000, the GlobalFilerTM kit performed even better with its CPI larger than 108 in 10 out of the 11 cases, much higher than that of Identifiler Plus kit. For the 39 duo cases, GlobalFiler^TM kit again elevated its CPI≥ 10,000 while the Identifiler Plus kit was only 30. Furthermore, GlobalFiler^TM kit can expose the genotyping of 21 autosome, Amelogenin, Y-indel and DYS391, especially with the last two exclusive loci for the kit to be capable of determining gender when samples are even of Y-allele-absence in Amelogenin. Conclusions GlobalFiler^TM kit, capable of amplifying more loci in a single run of amplification than the widely used Identifiler Plus kit, has greatly increased the CPI for identifying unknown bodies. Moreover, its additional Y-chromosome loci can help determine gender more effectively. Therefore, GlobalFiler^TM kit is high applicable in identifying tmknown bodies.

关 键 词:法医遗传学 STR基因座 Y等位基因缺失 GLOBAL Filer^TM试剂盒 骨骼 牙齿 累积父权指数 

分 类 号:DF795.2[医药卫生—法医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象