A coherence-based phase aberration correction method in medical ultrasound  被引量:7

A coherence-based phase aberration correction method in medical ultrasound

在线阅读下载全文

作  者:XIA Xinyuan LI Ping WU Wentao MENG Xiaohui 

机构地区:[1]Institute of Acoustics,Chinese Academy of Sciences [2]University of Chinese Academy of Sciences

出  处:《Chinese Journal of Acoustics》2015年第3期217-229,共13页声学学报(英文版)

基  金:supported by the National Natural Science Foundation of China(11204346)

摘  要:A coherence-based correction method was proposed in order to improve the lateral resolution and enhance the contrast of medical ultrasound imaging in the presence of phase aberration. The averaged coherence factor was proposed at first and used as a metric to evaluate phase aberration correction. By maximizing the averaged coherence factor, the time delay parameter of each channel was adjusted. A new set of coherence factors was calculated and the corrected data was optimized to form the final B-mode image. The simulations on point targets and a cyst phantom showed that the proposed method outperformed the nearest neighboring cross correlation method and conventional coherence-weighting method, and the lateral resolution and contrast ratio was improved by approximately 0.24mm and 18dB respectively. The proposed method combined the advantages of phase error correction and coherence-weighting, which could improve imaging qualities effectively in medical ultrasound.A coherence-based correction method was proposed in order to improve the lateral resolution and enhance the contrast of medical ultrasound imaging in the presence of phase aberration. The averaged coherence factor was proposed at first and used as a metric to evaluate phase aberration correction. By maximizing the averaged coherence factor, the time delay parameter of each channel was adjusted. A new set of coherence factors was calculated and the corrected data was optimized to form the final B-mode image. The simulations on point targets and a cyst phantom showed that the proposed method outperformed the nearest neighboring cross correlation method and conventional coherence-weighting method, and the lateral resolution and contrast ratio was improved by approximately 0.24mm and 18dB respectively. The proposed method combined the advantages of phase error correction and coherence-weighting, which could improve imaging qualities effectively in medical ultrasound.

关 键 词:A coherence-based phase aberration correction method in medical ultrasound Simulation MODE 

分 类 号:TB559[理学—物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象