出 处:《生物医学工程学杂志》2015年第5期1090-1095,共6页Journal of Biomedical Engineering
摘 要:评价18F-FDG PET心肌代谢显像、门控单光子发射计算机断层(GSPECT)心肌灌注显像、超声心动图(Echo)检测心肌梗死患者左心功能的应用价值,并进行比较。64例临床诊断为冠心病心肌梗死的患者,分别于2周内行PET、GSPECT及Echo中至少两种检查,测定左室舒张末期容积(EDV)、收缩末期容积(ESV)和射血分数(EF)值。将三种检查方法获得的左心功能参数进行两两比较,并行相关性分析及一致性检验。配对t检验发现,测量EDV时,18F-FDG PET较GSPECT高估10.63mL[(137.98±61.71)mL vs.(125.35±59.34)mL];测量ESV时,18F-FDG PET较Echo高估11.25mL[(85.89±55.21)mL vs.(68.22±41.37)mL],GSPECT较Echo高估17.88mL[(82.39±55.56)mLvs.(68.22±41.37)mL];测量EF时(GSPECT<18F-FDG PET<Echo,39.75%±15.64%vs.41.96%±15.08%vs.52.18%±13.87%),18 F-FDG PET较GSPECT高估3.85%,较Echo低估9.53%,GSPECT较Echo低估13.45%。PET、GSPECT和Echo测量左心功能的结果两两之间均存在较好的正相关关系(r=0.643~0.873,P值均为0.000)。Bland-Altman一致性检验结果提示,18 F-FDG PET与Echo测量左心功能的结果一致性好,可以相互参照;GSPECT与18 F-FDG PET测量ESV的结果和GSPECT与Echo测量EDV、EF的结果可以相互参照,其他指标GSPECT不能与18 F-FDG PET或Echo相互替换。因此,临床医师应根据患者的实际情况和检查目的决定检查方法。The aim of this study is to analyze the concordance between EDV, ESV and LVEF values derived from 18 F- FDG PET, GSPECT and ECHO in patients with myocardial infarction. Sixty four patients with coronary artery dis- ease (CAD) and myocardial infarction were enrolled in the study.. Each patient underwent at least two of the above mentioned studies within 2 weeks. LVEF. EDV and ESV values were analyzed with dedicated software. Statistical evaluation of correlation and agreement was carried out EDV was overestimated by 18F-FDG PET compared with GSPECT [-(137.98±61.71) mL and (125.35±59.34) mL~; ESV was overestimated by 18F FDG PET (85.89± 55.21) mL and GSPECT (82.39±55.56) mL compared with ECHO (68.22±41.37) mL; EF was overestimated by 18F-FDG PET (41.96%± 15.08%Q) and ECHO (52.18%± 13.87%) compared with GSPECT (39.75%±15.64%), and EF was also overestimated by 18F-FDG PET compared with GSPECT. The results of linear regres sion analysis showed good correlation between EDV, ESV and LVEF values derived from 18 F-FDG PET, GSPECT and ECHO (r=0. 643-0. 873, P= 0. 000). Bland-Ahman analysis indicated that 18 F-FDG PET correlated well withECHO in the Left ventricular function parameters. While GSPECT correlated well with 18F-FDG PET in ESV, GSPECT had good correlation with Echo in respect of EDV and EFV whereas GSPECT had poor correlation with PET/ECHO in the remaining left ventricular function parameters. Therefore, the clinical physicians should decide whether they would use the method according to the patients' situation and diagnostic requirements.
关 键 词:正电子发射计算机断层显像 单光子发射计算机断层显像 超声心动图 左心室功能 心肌梗死
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.20.238.29