±500kV直流线路导线布置对导线表面电场强度的影响  

Research on Effects of Conductor Arrangements on Surface Field Strength of Conductor in ± 500kV HVDC Transmission Line

在线阅读下载全文

作  者:陶优[1] 

机构地区:[1]云南开放大学,云南昆明650223

出  处:《科学与财富》2015年第10期239-239,238,共2页Sciences & Wealth

摘  要:导线表面电场强度取决于运行电压、子导线直径、分裂数、分裂间距、导线高度以及相间距离等。对±500kV直流线路导线表面电场强度进行计算,结果显示,导线表面电场强度受导线分裂根数、子导线直径的影响较大,导线高度和导线分裂间距影响较小。The surface field strength of a conductor depends on the running voltage, the diameter of sub-conductor, the number of bundled conductor, bundled wire pitch, The height of conductor, phase- to-phase distance, etc. The surface field strength of the conductor used in a ± 500kV HVDC Transmission Line is calculated. The result shows that the field strength is affected more by the number of bundled conductor and the diameter of sub-conductor and less by the height of the conductor and the bundled wire pitch.

关 键 词:高压直流输电线路 导线布置 表面电场强度 影响因素 

分 类 号:O441.1[理学—电磁学]

 