检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江省嘉兴市妇幼保健院产科,浙江嘉兴314000 [2]浙江省嘉兴市妇幼保健院麻醉科,浙江嘉兴314000
出 处:《中国医药导报》2015年第29期63-66,共4页China Medical Herald
基 金:浙江省嘉兴市科技计划项目(2013AY21050-4)
摘 要:目的 观察Cook宫颈扩张球囊联合硬膜外镇痛在足月引产中的临床效果。方法 选择2013年3月-2014年8月嘉兴妇幼保健院足月初产妇80例为研究对象,将其随机分为观察组与对照组,每组40例。观察组在Cook宫颈扩张球囊联合硬膜外镇痛下引产,对照组单纯采用Cook宫颈球囊引产。观察产程时间、产程结局、血流动力学指标、出血量、新生儿Apgar评分及不良反应,采集新生儿脐动脉血血气分析,测定引产前及分娩后例组产妇血常规白细胞计数和超敏C反应蛋白,总体评价产妇分娩舒适度。结果 观察组第一产程潜伏期明显短于对照组[(196.60±65.48)比(242.80±78.62)min],差异有高度统计学意义(P〈0.01),且观察组疼痛减轻;两组产程结局、出血量、新生儿Apgar评分、脐动脉血血气分析、引产术前及分娩后白细胞、超敏C反应蛋白比较,差异无统计学意义(P〉0.05)。两组收缩压、舒张压、心率比较,差异均有统计学意义(P〈0.05或P〈0.01),注药后0.5、1、2、3、4 h及结束时观察组视觉模拟评分均明显低于对照组(P〈0.05或P〈0.01)。结论 Cook宫颈扩张球囊联合硬膜外镇痛在足月引产中能明显缩短第一产程,减轻产妇疼痛,不增加感染概率,是一种安全有效的方法,可临床推广应用。Objective To explore the feasibility and effect of Cook balloon cervical dilator with epidural analgesia on full-term nulliparous parturients. Methods A total of 80 nulliparous parturients in Jinxing Maternity and Child Health Care Hospital from March 2013 to August 2014 were selected as study objects, and they were randomly divided into two groups, observation group(n=40) were received Cook balloon cervical dilator combined with epidural analgesia and control group(n=40) were received no epidural analgesia. The stage of labor, delivery outcome, parameters of hemodynamics, haemorrhage, Apgar scores of neonate and side effects were recorded. WBC and hypersensitive C-reactive protein of puerperas prenatal and after delivery were measured and blood gas analysis of umbilical artery blood of newborns was carried. Results Latent phase of lalor was shorter in observation group than in control group [(196.60±65.48)vs(242.80±78.62) min](P〈0.01). Moreover, the pain was relieved obviously. There were no significant differences in other labor duration, delivery outcome, haemorrhage, and Apgar scores between two groups(P〉0.05). SBP, DBP, HR of two groups had statistically significant differences(P〈0.05 or P〈0.01); 0.5, 1, 2, 3, 4 h after given medicine and the end of delivery, VAS scores of the observation group were significantly lower than those of the control group, the differences were statistically significant(P〈0.05 or P〈0.01). Conclusion Cook balloon can shorten latent phase of lalour, relieve the pain of parturients and not increase infection rate, it is worth the clinical application.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30