检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:简龙海[1] 孟茜[1] 陈丹丹[1] 郑荣[1] 钟吉强[1] 毛北萍[1] 王柯[1]
出 处:《香料香精化妆品》2015年第4期59-62,共4页Flavour Fragrance Cosmetics
摘 要:采用液相色谱-大气压化学离子化-三重四极杆质谱联用法(LC-APCI-MS/MS)测定化妆品中8种亚硝胺。色谱柱为Agilent Poroshell 120 EC-C18(4.6 mm×100 mm×2.7μm),质谱采用正离子MRM扫描方式。结果表明,待测物在5~100 ng/mL范围内线性关系良好,4种化妆品基质的加标回收率(添加水平分别为0.15、0.5和1.5 mg/kg)在63.1%~114.4%之间,相对标准偏差(RSD)在1.0%~7.8%范围内。A quantitative method for determination of 8 nitrosamines in cosmetics by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry( LC-APCI-MS / MS) was established. The sample was separated on an Agilent Poroshell120 EC-C18 column( 4. 6 mm × 100 mm × 2. 7 μm). The analytes were monitored by positive MRM mode. The calibration curve showed good linearity between 5 and 100 ng / m L. The recoveries( spiked at 0. 15,0. 5 and 1. 5 mg / kg,respectively) in 4 different types of cosmetics ranged from 63. 1% to 114. 4% and the RSD range was 1. 0% to 7. 8%.