检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:En-Dong Xing Long-Qi Liang Yu-Jie Dong Wei-Min Huang
机构地区:[1]College of Chemistry, Jilin University [2]Emergency Department, China–Japan Union Hospital of Jilin University
出 处:《Chinese Chemical Letters》2015年第10期1322-1326,共5页中国化学快报(英文版)
基 金:the National Natural Science Foundation of China (No.21273097);the project from the State Key Laboratory of Electroanalytical Chemistry (No.2013);the Science Foundation of Jilin Province (No.20130204003GX)
摘 要:The development of a simple, efficient and sensitive sensor for dissolved oxygen is proposed using a novel type of porous carbon composite membrane/glassy carbon electrode based on the low-cost common filter paper by a simple method. The resulting device exhibited excellent electrocatalytic activities toward the oxygen reduction reaction. Scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and electrochemical measurements demonstrated that the porous morphology and uniformly dispersed Fe;C nanoparticles of the PCCM play an important role in the oxygen reduction reaction. A linear response range from 2mmol/L up to 110 mmol/L and a detection limit of 1.4 mmol/L was obtained with this sensor. The repeatability of the proposed sensor,evaluated in terms of relative standard deviation, was 3.0%. The successful fabrication of PCCM/GC electrode may promote the development of new porous carbon oxygen reduction reaction material for the oxygen reduction sensor.The development of a simple, efficient and sensitive sensor for dissolved oxygen is proposed using a novel type of porous carbon composite membrane/glassy carbon electrode based on the low-cost common filter paper by a simple method. The resulting device exhibited excellent electrocatalytic activities toward the oxygen reduction reaction. Scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and electrochemical measurements demonstrated that the porous morphology and uniformly dispersed Fe_3C nanoparticles of the PCCM play an important role in the oxygen reduction reaction. A linear response range from 2mmol/L up to 110 mmol/L and a detection limit of 1.4 mmol/L was obtained with this sensor. The repeatability of the proposed sensor,evaluated in terms of relative standard deviation, was 3.0%. The successful fabrication of PCCM/GC electrode may promote the development of new porous carbon oxygen reduction reaction material for the oxygen reduction sensor.
关 键 词:Oxygen Sensor Porous carbon composite membrane Electrode
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.118.32.116