检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李旭东[1] 王明珠[1] 刘润明[1] 杜岳峰[1] 张琳[1] 王小宁[1] 康党鹏
机构地区:[1]西安交通大学医学院第一附属医院泌尿外科,陕西西安710061
出 处:《现代泌尿外科杂志》2015年第10期708-711,717,共5页Journal of Modern Urology
摘 要:目的评估单切口吊带(SIMS)治疗女性压力性尿失禁(SUI)的中期疗效及安全性;复习相关文献,提高对SIMS手术的认识。方法回顾性分析2013年4~8月所完成16例随访超过12个月(12~17月)的SIMS-adjust手术患者:年龄49~72岁,平均年龄61.2岁,病程3~17年,平均5.3年,体重指数22.6~34.1kg/m2,平均26.3kg/m2,分娩1~6次,平均2.2次;SUI分型Ⅰ型3例,Ⅱ型8例,Ⅲ型5例;残余尿量最高30mL,平均少于10mL,3例患者合并阴道前壁轻度脱垂,无尿流梗阻表现。终点指标包括有效性、安全性及患者满意度等。结果 16例患者手术均顺利,生活质量获得改善,1年期评分较基线降低(5.2±2.1)cm,所有患者术中出血均少于50mL,2例于术后6月及8月发生轻度尿失禁,1例术后3月开始性生活出现疼痛,1例排尿困难,残余尿量300mL,1例术后新发尿急,1例阴道吊带外露,1例左侧腹股沟区域疼痛,所有并发症治疗后均恢复。结论 SIMS-Ajust?)是治疗女性SUI的有效方法,手术1年期临床效果可靠,安全性高,术后并发症如腹股沟区疼痛、排尿困难及新发尿急的发生率均较低。术后恢复正常活动和工作时间较短。Objective To evaluate the mid-term efficacy and safety for adjustable single incision mini sling(SIMSAjust)treatment on female stress urinary incontinence(SUI).Methods A total of 16 cases undergone SIMS-Ajust were followed up over 12 months(2 to 17 months).The average age of patients was 61.2 years(49 to 72 years).The course of disease ranged from 3 to 17 years(average 5.3 years).The body mass index ranged from22.6 to 34.1 kg/m2(average 26.3 kg/m2).The delivery ranged from 1 to 6 times(average 2.2 times).SUI type I involved 3 cases,type II 8 cases and type Ⅲ 5 cases.The highest residual urine volume was 30 mL and averaged less than10 mL before operation.Altogether 3 cases had mild anterior vaginal wall prolapses,but none of them had urinary obstruction.The clinical data were retrospectively analyzed,including validity,security,patients'satisfaction.Results All operations were successful.The quality of life(QOL)was improved and decreased by(5.2±2.1)cm compared with baseline data within one year.All patients bled less than 50 mL.Mild incontinence occurred in 2 cases 6-8 months after surgery.Pain in sex occurred in 1 case 3 months after operation.Dysuria developed in 1 case,with300 mL residual urine.Urgency occurred in1 case.Vaginal tape erosion occurred in 1 case.Left groin pain occurred in 1 case.All complications were cured.Conclusion SIMS-Ajust is an effective treatment for female SUI.The clinical results and safety are satisfactory in 1 year.The incidence of complications,such as groin pain,dysuria and neourgency,is low.Patients can soon return to normal activities and work.
关 键 词:尿失禁 压力性 女性 尿道中段无张力悬吊术 单切口
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117