检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王博[1,2,3] 白永林[3] 曹伟伟[3] 徐鹏[3] 刘百玉[3] 缑永胜[1,2,3] 朱炳利[3] 候洵[1]
机构地区:[1]中国科学院西安光学精密机械研究所,瞬态光学与光子技术国家重点实验室,西安710119 [2]中国科学院大学,北京100049 [3]中国科学院西安光学精密机械研究所,超快诊断技术重点实验室,西安710119
出 处:《物理学报》2015年第20期140-146,共7页Acta Physica Sinica
基 金:国家自然科学基金(批准号:11305259,11327303);财政部重大科研装备仪器项目资助的课题~~
摘 要:高能密度物理研究中涉及许多单次皮秒现象的诊断测量,然而对单次X-ray脉冲形状、X-ray与激光脉冲的皮秒精度同步依然是极具挑战的课题.传统行波选通分幅相机受电子渡越时间限制,难以突破40 ps时间分辨极限.本文围绕半导体中光学探针光的全光调制效应,提出一种以低温GaAs材料为基础,实现皮秒时间分辨X-ray探测的新方法,详细阐述了该探测器的工作机理、器件参数设计和时间分辨能力.通过飞秒激光打靶实验,验证了其概念设计的正确性.结果表明该探测器具有约1.5 ps时间响应和10 ps时间分辨能力,通过材料优化可将时间分辨提升至1 ps以内.Diagnostic measurement of single picosecond event in high energy density physics,laser fusion,plasma radiation,and combustion,is of great importance.However,the measuring of the shape of the single X-ray pulse and the synchronization of X-ray and the laser pulse in picosecond resolution is still a great challenge.Restricted by the transit time of electrons,the time-resolution limit of a conventional framing camera based on the microchannel plate is 40 ps.Centered on the full-optical modulation effect of the light-probe,a novel method for X-ray detection of picoseconds temporal resolution based on low temperature GaAs is proposed in this work.The basic physical mechanism of the detector can be explained in both macroscopical and microcosmic ways.In the macroscopical way,the X-ray radiation absorption in the sensor material produces a transient,non-equilibrium electron-hole pair distribution that results in a transient differential change of the local refractive index,which is then sensed by the reflectivity changes of the optical probe beam.In the microcosmic way,X-ray absorption creates photoelectrons and the core level holes are subsequently filled through Auger or fluorescence processes.These excitations ultimately increase conduction and valence band carriers that perturb optical reflectivity.To verify the proposed X-ray detection method,a Fabry-Perot detector is designed,which consists of a 5(im thick GaAs layer surrounded by a GaAs/AlAs distributed Bragg reflector.The test is carried out on a femtosecond laser facility,where the X-ray source is produced by focusing the 56 fs Ti:Sapphire facility laser,with a central wavelength of 800 nm,onto an aluminum foil.Then the X-ray pulse induces a transient optical reflectivity change in GaAs,which is a powerful tool for establishing the high-speed X-ray detection.The experimental results indicate that this technology can be used to provide X-ray detectors with a temporal resolution of tens of picoseconds.By optimizing the material,the temporal resolution can be
分 类 号:O572[理学—粒子物理与原子核物理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.137.41.2