蒸汽发生器传热管动态特性研究  被引量:7

Study on Dynamic Characteristics of Heat Transfer Tube in SG

在线阅读下载全文

作  者:高李霞[1] 喻丹萍[1] 谭添才[1] 马建中[1] 刘理涛[1] 

机构地区:[1]中国核动力研究设计院,成都610213

出  处:《核动力工程》2015年第5期65-67,共3页Nuclear Power Engineering

摘  要:蒸汽发生器(SG)传热管束受二次侧横向流动流体的激励而产生的振动,是引起SG传热管失效的主要原因之一,传热管的固有频率和振型是进行流致振动响应分析评价的关键因素。采用理论分析与试验相结合的方式对ZH-65型SG的传热管开展动态特性研究,获得了传热管的固有频率和振型。试验值和计算值的相对偏差在8%以内。The secondary cross flow induced vibration of tube bundles of steam generator is the main failure reason of tubes. The flow induced vibration analysis and evaluations are based on the natural frequencies and modes of the heat transfer tube. A study on the dynamic characteristics of the heat transfer tube of a certain type steam generator have been carried out by calculation and experiment, and the natural frequencies and modes were obtained, and the relative deviations between measured and calculated values are within 8%.

关 键 词:传热管 动态特性 固有频率 

分 类 号:TL353[核科学技术—核技术及应用]

 