广西中医学院一附院水蓄冷设计  

Design of Air Conditioning System with Chilled Water Storage for First Affiliated Hospital of Guangxi Traditional Chinese Medical Collage

在线阅读下载全文

作  者:黄孝军 

机构地区:[1]华蓝设计(集团)有限公司

出  处:《建筑热能通风空调》2015年第5期94-96,26,共4页Building Energy & Environment

摘  要:本文以广西中医学院第一附属医院住院综合楼为例,分别配置常规空调方案及水蓄冷空调方案的冷热源设备,并对这两种空调设计方案的初投资及运行费用进行分析比较,根据计算数据得出结论,为设计师及业主以后在选择类似项目的空调方案时提供借鉴和参考。Taking the complex inpatient building of the First Affiliated Hospital of Guangxi Traditional Chinese Medical Collage for example, this paper is intended to show the designs of conventional central air conditioning system and the cold and heat source equipments in the chilled water storage air conditioning system. As a result, this paper provides reference for similar air conditioning schemes for designers and owners by comparing and analyzing the initial investment and operation cost of the three design schemes, and drawing a conclusion based on the calculation data.

关 键 词:常规空调 水蓄冷 冷热源设备 初投资 运行费用 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 