基于DSP2812的无功功率检测装置  

Three-Phrase Detection of Reactive Power Based on DSP 2812

在线阅读下载全文

作  者:张培杰[1] 公政[2] 姜文[2] 冯洁[1] 王安洋 公茂法[1] 

机构地区:[1]山东科技大学,山东青岛266590 [2]国网潍坊供电公司,山东潍坊261021

出  处:《电子质量》2015年第11期68-71,共4页Electronics Quality

摘  要:该文介绍了一种以DSP2812为主控的无功功率检测装置,采用瞬时无功功率理论,针对三相对称负载瞬时无功等同于平均无功的情况下,通过检测三相电压、电流瞬时值,实现对无功功率实时、准确地计算与检测,该文所采用的原理及算法简单易行,具有很强的工程实用性,适用于静止无功补偿装置(SVC)等需快速计算无功功率的工业控制系统。This paper presents a design of reactive power detection which uses DSP2812 as main control chip. As the case that symmetrical three phase load instantaneous reactive power equals to the average reactive power,by detecting three-phase voltage and current instantaneous value,we realized the real-timely and ac-curately calculate and detect of the reactive power with the instantaneous reactive power theory.Principles and algorithms used in this paper is simple and feasible for engineering,suitable for SVC and other reactive power industrial control systems which need quick calculation.

关 键 词:无功功率检测 瞬时无功功率 DSP 无功补偿 

分 类 号:TM933.3[电气工程—电力电子与电力传动]

 