检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨丽君[1] 唐美华[1] 张之翼[1] 高亚茹[1] 石成成[1] 张建枚 金栋[3] 陈国松[1]
机构地区:[1]南京工业大学,江苏南京210009 [2]北京市化工研究院,北京100013 [3]中国特种设备检测研究院,北京100013
出 处:《工业水处理》2015年第11期86-88,108,共4页Industrial Water Treatment
摘 要:建立了一种适用于含锌工业用水中痕量总铁测定的分光光度方法。在p H=9.00的条件下,用紫脲酸铵掩蔽Zn2+,用邻苯二酚紫与Fe2+反应生成蓝色络合物,以预先用邻菲罗啉掩蔽了Fe2+的显色体系为参比,605 nm处的吸光度与样品溶液中0.02~0.6 mg/L的Fe2+呈良好的线性关系,灵敏度约为邻菲罗啉法的5倍,检出限0.012 mg/L,加标回收率97.0%~100%,相对标准偏差1.16%。方法具有较高的灵敏度、准确度和重现性。A spectrophotometry method suitable for the determination of trace total iron in industrial water containing Zn2+ has been established. In the buffer solution when pH=9.00, murexide is used for masking Zn2+ and the reaction of pyrocatechol violet with Fe2+ forms a blue complex. Taking the chromagenic system whose Fe2+ has been masked by phenanthroline as reference solution,it is found that there is a good linear relationship between the absorbance of 605 nm and Fe2+ whose concentration is in the range of 0.02-0.6 mg/L in the sample solution. Meanwhile,the sensitivity of pyrocatechol violet spectrophotometry is about 5 times as much as that of phenanthroline spectrophotometry, detection limit is 0.012 mg/L,standard recovery rates are from 97% to 100% ,and relative standard deviation is 1.16%. The results indicate that the method has superior sensitivity, accuracy and reproducibility.