作 者:魏佩芳[1] 刘玉奇[2] 王丽燕[1] 薛静[1] 于丽玫[1] 穆晨[1] 桑晋秋[3] 洪焦[4] 孙超[2]
机构地区:[1]中国聋儿康复研究中心,北京100029 [2]哈尔滨工业大学,哈尔滨150001 [3]中国科学院声学研究所噪声与振动重点实验室,北京100190 [4]徐州市中心医院,徐州221000
出 处:《中国听力语言康复科学杂志》2015年第6期435-439,共5页Chinese Scientific Journal of Hearing and Speech Rehabilitation
基 金:“十二五”国家科技支撑计划项目子课题《听觉康复测评训练系统研制及应用示范》(2012BA134803)
摘 要:目的对一种自助听力测评系统进行初步临床评估,为其在大范围人群推广应用提供实验依据。方法95例志愿者采用自助听力测评系统在噪声小于45dB(A)的非隔声室环境下自主进行250、500、1000、2000、4000Hzl司值的测试,然后由专业人员采用GSI-61纯音听力计(在本底噪声低于30dB(A)的标准隔声室中)进行相同频率阈值的测试,计算各频率闽值差值。根据两种方法测得的平均听闽分别对所有受试者进行听力障碍分级,应用Kappa检验进行一致性分析。计算系统诊断中度及以上听力障碍的灵敏度和特异度。结果自助听力测评系统与纯音听力计测得的阈值吻合度较好。Kappa检验显示根据两种方法进行听力障碍分级的结果具有很好的一致性(Kappa=0.858,P=0.00)。系统诊断中度及以上听力损失的灵敏度为100%,特异度为98.9%。结论本自助听力测评系统提供了一种快速便捷的自助式听力测评方法,经对比试验验证测得的结果较为准确,但需进一步在较大规模人群中进行应用验证。Objectivo To conduct a preliminary clinical evaluation for an automated hearing test system in order to provide experimental evidences for its application to large-scale population. Methods A total of 95 volunteers performed a hearing test with the automated hearing test system by themselves in a quiet room with background noise less than 45 dB(A) and received pure-tone audiometry with GSI-61 clinical audiometer by audiologists in a soundproof room with background noise less than 30 dB(A). The hearing thresholds at 250,500, 1000, 2000 and 4000 Hz were obtained and the differences between the two methods were compared. The degree of hearing impairment of each volunteer was assessed according to the results of the two methods respectively and the Kappa test was applied to analyze the consistency of the results. The sensitivity and specificity of the system in detecting the moderate and more severe hearing impairment were calculated. Results The consistency of hearing thresholds between automated hearing test system and pure-tone audiometer was good. Kappa test showed that there was a good consistency in the hearing rating results between the two methods(Kappa=0.858,P=0.00).The sensitively of the system in detecting the moderate and more severe hearing impairment was 100% and the specificity was 98.9%. Conclusion This system provides a quick and convenient automated hearing test method, and can obtain a relatively accurate result. However, the system should be further assessed in large-scale population.
分 类 号:R851.3[医药卫生—航空、航天与航海医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.118.253.134