铝电解车间氟化物和粉尘排放测试研究  被引量:2

Testing Research of Fluoride and Dust Emission in Aluminum Electrolysis Workshop

在线阅读下载全文

作  者:何爱玲[1] 李锐[2] 李巍[1] 

机构地区:[1]沈阳环境科学研究院,辽宁沈阳110016 [2]沈阳市环境保护局沈河分局,辽宁沈阳110003

出  处:《环境保护科学》2015年第5期128-130,152,共4页Environmental Protection Science

摘  要:3文章对某500 k A系列电解槽排放的电解烟气进行测试。净化系统出口处的粉尘平均含量为15.0 mg/Nm,总氟平3 3均含量为0.8 mg/Nm;天窗排放的粉尘和氟化物的时间加权平均浓度分别是4.4、0.32 mg/Nm;两处测试数据中粉尘和总氟3均能分别满足《铝工业污染物排放标准》(GB 25465—2010)规定的20.0、3.0 mg/Nm标准限值要求。电解槽的总氟集气效率为97.20%。除尘器的漏风率为0.56%,粉尘的净化效率是99.97%,氟化物的净化效率是99.7%。测试结果表明电解槽集气效率偏低,故为减少电解烟气污染物排放,应对现有设计进行改进,提高电解槽集气效率。In this paper, the electrolytic fumes from 500 k A series electrolytic tank were detected. At the outlet of the 3 3purification system, the average content of dust was 15.0 mg/Nm and that of the total fluorine was 0.8 mg/Nm^3. The time weighted 3 3average concentrations of dust and fluoride emitted from the skylight were 4.4 mg/Nm^3 and 0.32 mg/Nm^3 respectively. The test data 3 3of dust and total fluoride in two places satisfied the standard limit of 20.0 mg/Nm^3 and 3.0 mg/Nm^3 respectively stipulated in the Emission Standard of Pollutants for Aluminum Industry(GB25465-2010). The total fluorine gas efficiency of electrolytic tank was 97.20%. The air leakage rate of dust collector was 0.56%. The purification efficiency of dust and fluoride was 99.97% and 99.7% respectively. The testing results showed that the gas collecting efficiency of electrolytic tank was low. Therefore, the existing design should be revised to improve the gas collecting efficiency of electrolytic tank for reduction of the electrolytic flue gas emission.

关 键 词:电解铝 氟化物 粉尘 测试 

分 类 号:X511[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象