检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]国网浙江省电力公司杭州供电公司,杭州310009
出 处:《浙江电力》2015年第11期1-4,共4页Zhejiang Electric Power
摘 要:分析了电流法、电压法检查变压器套管电流互感器变比的原理以及主要特点,提出了一种基于多抽头电流互感器二次侧自耦原理的简便检查方法。通过试验验证和现场的实际应用情况可知,该方法相比于电流法和电压法,极大地简化了检查过程,有效降低工作量和规避作业风险,具有设备精简便携、试验接线简单、操作方便等优点,检查正确率达到100%。The paper analyzes principles and main characteristics of current method and voltage method for checking transformation ratio between transformer and bushing current transformer and puts forward a simple check method based on self-coupling at secondary side of multi-tap current transformer. Through test validation and field application, it is proved that the new method, in contrast with current method and voltage method, can greatly simplify the check process, reduce the work load and avoid operation risks; it is also characterized by device portability, simple test connection, convenient operation, etc. The correct check rate can be up to 100%.