作 者:杨勇[1,2] 刘如月[1] 赵登攀[1] 吴波[2] 邓辉[1]
机构地区:[1]西安建筑科技大学土木工程学院,陕西西安710055 [2]华南理工大学亚热带建筑科学国家重点实验室,广东广州510640
出 处:《建筑结构学报》2015年第12期99-105,共7页Journal of Building Structures
基 金:亚热带建筑科学国家重点实验室自主研究课题(X2JZ-C710071Z);西安建筑科技大学创新团队资助计划
摘 要:为提高钢筋混凝土异形柱的受力性能,在钢筋混凝土异形柱中设置钢管高强混凝土芯柱,形成内置钢管高强混凝土芯柱的组合异形柱。为研究该类型组合异形柱在历经高温后的受压性能,开展了3个足尺十字形组合异形柱试件在历经ISO 834标准明火试验后的轴压试验和1个未受火组合异形柱试件的轴压试验,分析了不同受火时间对内置钢管高强混凝土芯柱的组合异形柱的破坏形态、轴向变形和轴向承载能力的影响。结果表明:处于试件内部的芯柱承载力高且升温较慢,由芯柱所提供的轴向承载能力和竖向刚度受高温影响较小,受火时间为90 min和120 min异形柱试件的剩余承载力系数分别为0.839和0.761,具有较高的剩余轴压承载力。To improve the mechanical performance of the reinforced concrete special shape column,a high strength concrete filled steel tubular( CFST) core column was utilized. In order to investigate the after-fire performance of this kind of composite special shape column,tests of four full-scale composite cross shape column specimens were conducted. Three of these specimens were firstly burned under ISO 834 standard fire and then axially compressed to failure,while the fourth composite column specimen was only axially compressed to failure. The effects of the firing time on the after-fire failure patterns,axial force capacity,axial deformation of the CFST core column was analyzed.The test results indicate that the CFST core column is very beneficial to improve and sustain the after-fire capacity and rigidity of the special shape column,because the core column in the center of the column is difficult to heat up. The effect caused by fire on axial compression capacity and axial rigidity of the core column is slight. The CFST core column can sustain high axial capacity, the residual axial compression capacity ratio is 0. 839 and 0. 761,respectively,corresponding to the time of 90 min and 120 min,respectively.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117