1065 t/h机组锅炉引风机性能试验及分析  

1065 t/h Boiler Induced Draft fan Performance Test and Analysis

在线阅读下载全文

作  者:谷聪伟 陈鹏飞[1] 徐绍宗 邹天舒 李智[1] 

机构地区:[1]沈阳工程学院能源与动力学院,辽宁沈阳110136 [2]东北电力科学研究院有限公司锅炉技术研究所,辽宁沈阳110006

出  处:《锅炉制造》2015年第6期5-8,15,共5页Boiler Manufacturing

摘  要:某热电厂为节能降耗,降低厂用电,在大修期间,将原设计的2台引风机改为动叶可调式轴流引风机。对改造后的风机进行性能试验,测量并计算三种不同负荷下风机性能数据。结果表明,改造后的动叶可调轴流风机能适应不同负荷工况,基本达到设计参数。由于煤质变化和锅炉烟气量变化,引风机效率与设计之有一定偏差,但可满足运行要求。In order to save energy and reduce auxiliary power, during the overhaul, a thermal power plant changed the original two induced fan design to variable pitch axial -flow induced draft fan. After transformation, measuring and calculating the fan performance data at three different loads. The results show that after the transformation of the adjustable rotor blade axial fan can adapt to different load conditions, basically meet the design parameters. Due to changes in coal quality and boiler flue gas volume, Fan efficiency and design values have a certain bias, but can meet the oper- ational requirements.

关 键 词:引风机 性能试验 效率 

分 类 号:TK223.26[动力工程及工程热物理—动力机械及工程]

 