检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海交通大学生物医学工程学院,上海200030
出 处:《CT理论与应用研究(中英文)》2015年第4期475-483,共9页Computerized Tomography Theory and Applications
基 金:performed at the BL13W beam line of Shanghai Synchrotron Radiation Facility(SSRF);supported by the National Basic Research Program of China(973 Program;2010CB834302)
摘 要:数字X光层析成像由于其低辐射剂量和增强的图像对比度,广泛应用于医学诊断中。结合X光相衬成像的优异的软组织成像能力,X光相衬层析成像方法可以获得更好的软组织成像能力。本文的目的是提出一种快速的、低辐射剂量的X光相衬层析成像方法及算法。本方法在数据采集过程中光栅的位移和样品的旋转同时进行,它区别于传统的相位步进方法,采集到的数据是不完全的。我们提出了一种新型的重建方法,即内聚焦式重建。实验验证了提出的快速光栅相衬层析成像方法,结果表明在同等辐射剂量情况下,快速光栅相衬层析成像优于传统的基于相位步进的方法。由于快速光栅相衬层析成像采用连续的物体转动和光栅移动,其成像速度更快,避免了潜在的运动伪影。As an imaging technique with low radiation dose and improved contrast, digital X-ray tomosynthesis is widely used in clinical diagnoses. Based on the superior capability of X-ray phase-contrast imaging(PCI) techniques for imaging low density materials, the combination of X-ray tomosynthesis and PCI could potentially provide higher efficiency in the detection of soft tissues. The goal of this work was to develop a fast and low-dose imaging method for phase-contrast tomosynthesis, called grating-based phase-contrast tomosynthesis(GPC-Tomo), which integrates tomosynthesis with a grating-based PCI technique. During data acquisition with the proposed fast GPC-Tomo, the grating scanning and sample rotation occur at the same time, which is different from the scheme used for conventional GPC-Tomo. Without the phase stepping(PS) technique to extract the differential phase-contrast image at each projection angle for the conventional GPC-Tomo, the data collected by the fast GPC-Tomo is incomplete. Here, we propose a novel reconstruction method called inner-focusing(IF) reconstruction for the proposed fast GPC-Tomo. In the reconstruction stage, measured X-ray intensities from neighboring projection angles that pass through the reconstructed point are utilized to compose a stepping period for signal extraction. The proposed fast GPC-Tomo technique was validated by real experiments. The results demonstrated that the reconstructed images acquired with the fast GPC-Tomo are better than those acquired with conventional GPC-Tomo, and with near-equivalence in radiation dose. Furthermore, since the proposed fast GPC-Tomo employs continuous rotation, its scanning time is much less than the stop-and-go motion of the conventional GPC-Tomo.(School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China)
分 类 号:TP391.41[自动化与计算机技术—计算机应用技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15