HM-JD-L28型新型石墨复合接地体与常规降阻方式降阻效果的对比分析  被引量:9

Comparative Analysis of HM-JD-L28 Composited Grounding Conductor and Routine Grounding Resistance Reducing Measure

在线阅读下载全文

作  者:龚若涵 

机构地区:[1]武汉大学电气工程学院,武汉430072

出  处:《电瓷避雷器》2015年第6期69-72,79,共5页Insulators and Surge Arresters

摘  要:输电线路杆塔接地对电力系统的安全稳定运行至关重要,降低杆塔接地电阻是提高线路耐雷水平,减少线路雷击跳闸率的主要措施。介绍了HM-JD-L28型新型石墨复合接地体的性能特点并将其与常规降阻方式如:接地模块、降阻剂、增加射线长度等在不同情况下的降阻效果进行了分析对比,对如何使用接地模块、降阻剂提出了意见:不推荐在土壤电阻率低于500Ωm的地区使用接地模块及降阻剂,降阻效果不明显。The grounding system of transmission lines tower play an important role for the stability of the power grid, the main measure to improve lightning withstand level and reduce lightning trip-out rate is reducing grounding resistance. The characteristic of HM-JD-L28 composited grounding conductor is introduced, and several common grounding grounding module, resistance reducing agent and resistance reducing measures such as: increasing the length of grounding conductor are analyzed and compared, suggestions about the usage and effect of grounding module and resistance reducing agent are proposed: using grounding module and resistance reducing agent in the soil where resistivity is lower than 500 Ωm is not recommended, because the resistance reducing effect is not obvious.

关 键 词:HM-JD-L28型新型石墨复合接地体 降阻剂 接地模块 工频接地电阻 降阻效果 