职业接触者尿中汞微波消解—原子荧光法测定  被引量:7

Determination of urinary mercury among workers with occupational exposure by atomic fluorescence spectrometry and microwave digestion

在线阅读下载全文

作  者:姜枫[1] 蒋莹[1] 王军明[1] 

机构地区:[1]辽宁省职业病防治院,沈阳110005

出  处:《中国公共卫生》2015年第12期1629-1631,共3页Chinese Journal of Public Health

摘  要:目的建立职业汞接触者尿汞水平的原子荧光测定法。方法用微波消解法对尿样进行前处理,处理后无需赶酸,用5%硝酸溶液做载液,在灯电流15mA,负高压240V,原子化高度8mm,载气流量(血气)400mL/min,屏蔽气流量1000mL/min条件下,用0.5g/L硼氢化钾溶液作还原剂做工作曲线测定职业接触者尿中汞浓度。结果该方法在0.01—10.00ug/L范围内具有良好线性关系,r=0.9996,检出限为0.01ug/L,回收率100.O%~107.8%,相对标准偏差(RSD)为2.07%-4.26%。结论该方法可作为职业汞接触者体内汞接触水平的检测方法。Objective To establish a method to detect urinary mercury among workers with occupational exposure by atomic fluorescence spectrometry(AFS) and microwave digestion. Methods The urine specimens from workers with oecupational mercury exposure were treated with microwave digestion and then the mercury in the specimens was determined with hydride generation AFS. Results The method showed a good linearity in the range of mercury concentration of 0. 01 -10 ug/L (r = 0. 999 6) and a detection limit of 0. 01 ug/L; the recovery rates of the method ranged from 100.0% to 107. 8% ,with the relative standard deviations of 2.07% -4. 26%. Conclusion The method could be used to monitor mercury level in vivo among workers with occupational exposure.

关 键 词:微波消解 尿汞水平 原子荧光法 工作曲线 

分 类 号:R13[医药卫生—劳动卫生]

 