检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李瑞 王忠旭[2] Derrick Holliday 姚良忠[3] Barry W.Williams
机构地区:[1]Department of Electronic and Electrical Engineering University of Strathclyde, Glasgow G1 1XW [2]哈尔滨工业大学电气工程及自动化学院,哈尔滨150001 [3]中国电力科学研究院,北京100192
出 处:《电源学报》2015年第6期28-35,共8页Journal of Power Supply
基 金:EPSRC项目(EP/K006428/1,EP/K035096);国家自然科学基金项目(51261130484)~~
摘 要:为了降低模块化多电平变换器MMC(modular multilevel converter)的接线复杂度和通信失效故障概率,ABB提出了采用压接式IGBT串联的级联两电平CTL(cascaded two-level)变换器。由于桥臂子模块数由数百降为几十,CTL变换器输出电压电平数较少,需要在交流侧安装滤波器。为此,提出了基于三电平TL(three-level)子模块的倍电平复合式MMC变换器VLD-HMMC(voltage-level-doubler hybrid MMC)。每个桥臂有TL、半桥HB(halfbridge)子模块混合组成,且交流侧串联有一个全桥FB(full-bridge)子模块,输出电压电平数提高了1倍,从而省去了交流滤波器。各子模块具有脉冲自主触发功能且其功率开关由压接式器件串联组成,降低了桥臂子模块数,简化了控制器与主电路之间的接线复杂度,降低了通信故障的概率。单个功率开关短路故障不会影响系统正常运行,并且可避免了子模块电容的过度放电,保护电容器和功率开关,提高变换器的可靠性及故障穿越能力。所提拓扑结构实现了直流故障穿越运行,为HVDC换流站的设计提供了技术参考。The cascaded two-level(CTL) converter based on series-connected press-pack IGBTs is proposed by ABB to simplify the line connection complexity of a modular multilevel converter(MMC) and reduce the communication failure possibility. As the submodules per arm are reduced from several hundreds to several tens, the CTL converter has fewer output voltage levels and an at-side filter is required to reduce harmonies. To tackle this problem, the three-level (TL) submodule based voltage-level-doubler hybrid MMC (VLD-HMMC) is proposed, where the TL submodules and half-bridge (HB) submodules are mixed in each arm and a full-bridge(FB) submodule is connected in series on the ac-side. The output vohage levels are doubled and thus any ac filter requirements are avoided. The submodule modulation is made semi-autonomous and the power devices are composed of series-connected press-pack semiconductors. As a result, the submodules per ann are reduced and the connection between controller and the main power circuit is simplified, yielding lower communication failure probability. When a short-circuit fault is applied across one switching device, the system can still operate normally and the over-discharge of submodule capacitors as well as the damage to capacitors and power switches are avoided. This improves the converter reliability and contributes to dc fault ridethrough operation. The proposed topology with dc fault blocking capability provides an attractive approach for the development of HVDC power stations.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.44