检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《工程热物理学报》2015年第12期2730-2732,共3页Journal of Engineering Thermophysics
基 金:国家自然科学基金面上项目(No.51376098)
摘 要:燃气轮机驱动的冷热电三联供系统是我国近年来大力鼓励发展的小型能源供应系统,将蓄能装置与联供系统结合对系统供能设备能起到减容增效的作用。本文建立了相变蓄能型联供系统的简化数学模型,提出了在给定实际用户负荷的情况下,以一次能耗最小为优化目标的最佳相变温度确定方法。典型算例分析表明,相变型烟气蓄热器的最优相变温度与用户负荷及设备性能相关,相比于NTU无限大,NTU有限大时,最优相变温度会升高,最小一次能耗会增大。Natural gas driven Building Cooling Heating and Power(BCHP) system is encouraged to develop as small-scale energy supply system in recent years.In this paper,a thermodynamic model of BCHP system with phase change material(PCM) energy storage is established.According to practical user loads and considering the correspondingly hourly changing flow rate in charge and discharge processes,a simplified method is proposed to determine the optimal phase change temperature for BCHP-TES,aiming to minimize the primary energy consumption of BCHP-TES system.An illustrative example shows that the optimal phase change temperature can be obtained for given loads.It also indicates that compared to infinite NTU for PCM-TES,the optimal phase change temperature will increase as well as the corresponding minimal primary energy consumption for finite NTU.This work is of great importance for PCM optimization of BCHP-TES system design.
分 类 号:TK16[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.52