探针扫描法快速测量半导体激光阵列Smile效应  被引量:5

Smile effect of laser diode arrays measured by stylus scan method

在线阅读下载全文

作  者:贾冠男[1] 尧舜[1] 潘飞[1] 高祥宇[1] 王智勇[1] 

机构地区:[1]北京工业大学激光工程研究院,北京100124

出  处:《红外与激光工程》2015年第12期3576-3579,共4页Infrared and Laser Engineering

基  金:北京市委组织部优秀人才培养计划(2012D005015000005);北京市教委项目(KM201110005017)

摘  要:为克服传统光学方法测量半导体激光阵列(LDA)Smile效应时存在的光学系统搭建精度要求高、测试人员素质要求高、后期数据处理繁杂测量时间长等缺点,通过用机械接触式台阶仪的探针扫描焊接后LDA芯片N面的方式,快速测量LDA的Smile效应,并将之与传统光学方法测量的Smile效应进行对比。结果表明,两者形态完全一致,差别小于1μm。用台阶仪测量LDA Smile效应耗时小于1 min。此方法能为芯片焊接工艺优化Smile效应提供快速反馈,可方便集成在大批量生产流水线中对LDA的Smile效应进行实时监测。Traditional optical methods which are used to measure the Smile effect of laser diode arrays (LDA) have problems such as high precision optical system setting up, high operator quality requirements, vast and complex subsequent data processing, long measuring time and so on. In this paper, a new method that scanned the N side of mounted LDA chips with the stylus of a mechanical contacting profiler was proposed to measure the Smile effect of LDA quickly. The measuring result was compared with the Smile effect measured by a traditional optical method. And the comparision indicates that their shapes are uniform and the difference is less than 1 micrometre. Using a profiler to measure the Smile effect of LDA takes little time less than 1 minute. The method can provide feedbacks quickly in chips bonding process to minimize the Smile effect, and can be easily integrated into high production lines to monitor the Smile effect of laser diode arrays in real time.

关 键 词:激光器 半导体激光阵列 Smile效应 光束质量 

分 类 号:TN248.4[电子电信—物理电子学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象