南京西环网装设UPFC装置的主设备容量优化选择  被引量:9

The Optimal Capacity Selection of UPFC Installed in Nanjing 220 kV Western Power Grid

在线阅读下载全文

作  者:甄宏宁 梁志瑞[2] 王莹 王震泉[1] 张诗滔[1] 

机构地区:[1]江苏省电力设计院,江苏南京211102 [2]华北电力大学,河北保定071000

出  处:《江苏电机工程》2015年第6期18-22,共5页Jiangsu Electrical Engineering

摘  要:为了解决近期及未来南京主城区220 k V西环网存在输电通道瓶颈的问题,电力规划部门决定采取在电网中串接统一潮流控制器(UPFC)的措施。文中结合当地电网实际情况提出了UPFC容量选择的方法和思路。借助电力系统综合分析程序(PSASP),通过潮流稳态计算,进行了UPFC容量对提升南京西环网供电能力的敏感性分析,并且提出了UPFC最优容量选择。In order to solve the transmission channel bottleneck problem will occur in Nanjing 220 k V western grid, a series unified power flow controller(UPFC) is planned to install into the grid. Considering the actual situation of the power grid, a method for selecting the UPFC capacity is proposed. In this method, sensitivity analysis of UPFC capacity to promote Nanjing western network supply ability is given through power flow calculation in PSASP. Finally, the suitable UPFC capacity for Nanjing 220 k V western power grid is presented.

关 键 词:UPFC 南京西环网 容量选择 

分 类 号:TM744[电气工程—电力系统及自动化]

 